Abstract

Instrument-assisted soft tissue mobilization (IASTM) is a manual therapy technique that is commonly used to treat dysfunctions in ligaments and other musculoskeletal tissues. The objective of this study was to develop a simple hand-held device that helps users accurately apply targeted compressive forces and stroke frequencies during IASTM treatments. This portable device uses a force sensor, tablet computer, and custom software to guide the application of user-specified loading parameters. To measure performance, the device was used to apply a combination of targeted forces and stroke frequencies to foam blocks and silicone pads. Three operators using the device applied targeted forces between 0.3 and 125 N with less than 10% error and applied targeted stroke frequencies between 0.25 and 1.0 Hz with less than 3% error. The mean error in applying targeted forces increased significantly at compressive forces less than 0.2 N and greater than 125 N. For experimental validation, the device was used to apply a series of IASTM treatments over three-weeks to rodents with a ligament injury, and the targeted compressive force and stroke frequency were repeatedly applied with an average error less than 5%. This validated device can be used to investigate the effect of IASTM loading parameters on tissue healing in animal and human studies, and therefore can support the optimization and adoption of IASTM protocols that improve patient outcomes.

Entities:  

Keywords:  IASTM; manual therapy; massage; mechanotransduction; medial collateral ligament; tendinopathy

Year:  2018        PMID: 30662581      PMCID: PMC6298531          DOI: 10.1115/1.4041696

Source DB:  PubMed          Journal:  J Med Device        ISSN: 1932-6181            Impact factor:   0.582


  15 in total

1.  Three-dimensionality of contact forces during clinical manual examination and treatment: a new measuring system.

Authors:  Gerrit G J M van Zoest; Henk T C M van den Berg; Fred C Holtkamp
Journal:  Clin Biomech (Bristol, Avon)       Date:  2002 Nov-Dec       Impact factor: 2.063

2.  Design and construction of a novel low-cost device to provide feedback on manually applied forces.

Authors:  Neil Tuttle; Guillermo Jacuinde
Journal:  J Orthop Sports Phys Ther       Date:  2011-01-05       Impact factor: 4.751

3.  Three-dimensional manual contact force evaluation of graded perpendicular push force delivery by second-year physiotherapy students during simple feedback training.

Authors:  Gerrit G J M van Zoest; Filip F G M Staes; Karel H Stappaerts
Journal:  J Manipulative Physiol Ther       Date:  2007 Jul-Aug       Impact factor: 1.437

4.  Quantitative application of transverse friction massage and its neurological effects on flexor carpi radialis.

Authors:  Hsin-Min Lee; Shyi-Kuen Wu; Jia-Yuan You
Journal:  Man Ther       Date:  2008-11-22

Review 5.  What is the clinical course of acute ankle sprains? A systematic literature review.

Authors:  Rogier M van Rijn; Anton G van Os; Roos M D Bernsen; Pim A Luijsterburg; Bart W Koes; Sita M A Bierma-Zeinstra
Journal:  Am J Med       Date:  2008-04       Impact factor: 4.965

6.  Fibroblast responses to variation in soft tissue mobilization pressure.

Authors:  G M Gehlsen; L R Ganion; R Helfst
Journal:  Med Sci Sports Exerc       Date:  1999-04       Impact factor: 5.411

7.  Instrument-assisted cross-fiber massage accelerates knee ligament healing.

Authors:  M Terry Loghmani; Stuart J Warden
Journal:  J Orthop Sports Phys Ther       Date:  2009-07       Impact factor: 4.751

8.  Epidemiology of lower extremity injuries among U.S. high school athletes.

Authors:  William G Fernandez; Ellen E Yard; R Dawn Comstock
Journal:  Acad Emerg Med       Date:  2007-05-18       Impact factor: 3.451

9.  Conservative treatment of a female collegiate volleyball player with costochondritis.

Authors:  Donald Aspegren; Tom Hyde; Matt Miller
Journal:  J Manipulative Physiol Ther       Date:  2007-05       Impact factor: 1.437

10.  A mechatronic system for quantitative application and assessment of massage-like actions in small animals.

Authors:  Qian Wang; Hansong Zeng; Thomas M Best; Caroline Haas; Ned T Heffner; Sudha Agarwal; Yi Zhao
Journal:  Ann Biomed Eng       Date:  2013-08-14       Impact factor: 3.934

View more