L Ellegård1, A Aldenbratt2, M K Svensson2, C Lindberg3. 1. Department of Internal Medicine and Clinical Nutrition, Sahlgrenska Academy at the University of Gothenburg, Gothenburg, Sweden. Electronic address: lasse.ellegard@nutrition.gu.se. 2. Department of Medical Sciences, Uppsala University, Uppsala, Sweden. 3. Department of Neurology, Neuromuscular Centre, Sahlgrenska University Hospital, Gothenburg, Sweden.
Abstract
BACKGROUND: Patients with primary neuromuscular disease have reduced muscle mass, and use of body mass index to assess nutritional status and body composition can therefore be questioned. Dual emission X-ray absorptiometry (DXA) can estimate muscle mass, but is not always readily available. Bioimpedance is a simple, portable and "easy to use" method for the assessment of body composition. OBJECTIVES: To assess muscle mass by DXA in 143 patients with primary neuromuscular disease and validate three bioimpedance devices; Impedimed SFB7, (BISIMPEDIMED), Xitron4200 (BISXITRON) and Tanita MC180MA (MFBIATANITA). METHODS: Body composition was assessed by DXA in 143, by BISIMPEDIMED in 116, by MFBIATANITA in 104 and by BISXITRON in 35 patients. RESULTS: Muscle mass assessed by DXA, and phase angle (PhA) were below reference values in all female and 96% of male patients. BISIMPEDIMED underestimated muscle mass by 6.5 ± 14.2 kg (p < 0.001), but this could be corrected after exclusion of resistance (Ri) values > 3500 Ohm (p = 0.84). MFBIATANITA overestimated muscle mass by 30.8 ± 9.1 kg (p < 0.001) with systematic bias, whereas BISXITRON was in agreement with DXA, and without systematic bias. Muscle mass was strongly correlated to PhA (rPEARSON = 0.75, p < 0.01). CONCLUSION: Patients with primary neuromuscular disease have proportionally more fat and less muscle mass than the population in general, despite normal BMI. Muscle mass can be assessed by bioimpedance in these patients, but performance and bias depends on device. Phase angle by bioimpedance correlates to muscle mass, and could therefore potentially be used a surrogate measure of muscle mass during follow up.
BACKGROUND:Patients with primary neuromuscular disease have reduced muscle mass, and use of body mass index to assess nutritional status and body composition can therefore be questioned. Dual emission X-ray absorptiometry (DXA) can estimate muscle mass, but is not always readily available. Bioimpedance is a simple, portable and "easy to use" method for the assessment of body composition. OBJECTIVES: To assess muscle mass by DXA in 143 patients with primary neuromuscular disease and validate three bioimpedance devices; Impedimed SFB7, (BISIMPEDIMED), Xitron4200 (BISXITRON) and Tanita MC180MA (MFBIATANITA). METHODS: Body composition was assessed by DXA in 143, by BISIMPEDIMED in 116, by MFBIATANITA in 104 and by BISXITRON in 35 patients. RESULTS: Muscle mass assessed by DXA, and phase angle (PhA) were below reference values in all female and 96% of male patients. BISIMPEDIMED underestimated muscle mass by 6.5 ± 14.2 kg (p < 0.001), but this could be corrected after exclusion of resistance (Ri) values > 3500 Ohm (p = 0.84). MFBIATANITA overestimated muscle mass by 30.8 ± 9.1 kg (p < 0.001) with systematic bias, whereas BISXITRON was in agreement with DXA, and without systematic bias. Muscle mass was strongly correlated to PhA (rPEARSON = 0.75, p < 0.01). CONCLUSION:Patients with primary neuromuscular disease have proportionally more fat and less muscle mass than the population in general, despite normal BMI. Muscle mass can be assessed by bioimpedance in these patients, but performance and bias depends on device. Phase angle by bioimpedance correlates to muscle mass, and could therefore potentially be used a surrogate measure of muscle mass during follow up.
Authors: David Naranjo-Hernández; Javier Reina-Tosina; Laura M Roa; Gerardo Barbarov-Rostán; Nuria Aresté-Fosalba; Alfonso Lara-Ruiz; Pilar Cejudo-Ramos; Francisco Ortega-Ruiz Journal: Sensors (Basel) Date: 2019-12-21 Impact factor: 3.576