Heart rate measures from the Apple Watch, Fitbit Charge HR 2, and electrocardiogram across different exercise intensities.

Elizabeth A Thomson1, Kayla Nuss1, Ashley Comstock1, Steven Reinwald1, Sophie Blake1, Richard E Pimentel1, Brian L Tracy1, Kaigang Li1.   

Abstract

This study compared heart rate (HR) measurements for the Fitbit Charge HR 2 (Fitbit) and the Apple Watch devices with HR measurements for electrocardiogram (ECG). Thirty young adults (15/15 females/males, age 23.5 ± 3.0 years) completed the Bruce Protocol. HR measurements were recorded from the ECG and both devices every minute. Average HR for each participant was calculated for very light, light, moderate, vigorous and very vigorous intensities based on ECG-measured HR. A concordance correlation coefficient (CCC) was calculated to examine the strength of the relationship between ECG measured HR and HR measured by each device. Relative error rates (RER) were also calculated to indicate the difference between each device and ECG. An equivalence test was conducted to examine the equivalence of HRs measured by devices and ECG. The Apple Watch showed lower RER (2.4-5.1%) compared with the Fitbit (3.9-13.5%) for all exercise intensities. For both devices, the strongest relationship with ECG-measured HR was found for very light PA with very high CCC (>.90) and equivalence. The strength of the relationship declined as exercise intensity increased for both devices. These findings indicate that the accuracy of real-time HR monitoring by the Apple Watch and Fitbit Charge HR2 is reduced as exercise intensity increases.

Entities:  

Keywords:  Apple Watch; Fitbit Charge HR 2; Heart rate measurement; exercise intensity; wearable devices

Mesh:

Year:  2019        PMID: 30657025     DOI: 10.1080/02640414.2018.1560644

Source DB:  PubMed          Journal:  J Sports Sci        ISSN: 0264-0414            Impact factor:   3.337


  26 in total

Review 1.  Innovations in research and clinical care using patient-generated health data.

Authors:  Heather S L Jim; Aasha I Hoogland; Naomi C Brownstein; Anna Barata; Adam P Dicker; Hans Knoop; Brian D Gonzalez; Randa Perkins; Dana Rollison; Scott M Gilbert; Ronica Nanda; Anders Berglund; Ross Mitchell; Peter A S Johnstone
Journal:  CA Cancer J Clin       Date:  2020-04-20       Impact factor: 508.702

2.  Biosensors for Personal Mobile Health: A System Architecture Perspective.

Authors:  Siddarth Arumugam; David A M Colburn; Samuel K Sia
Journal:  Adv Mater Technol       Date:  2019-11-20

3.  Recommendations for determining the validity of consumer wearable heart rate devices: expert statement and checklist of the INTERLIVE Network.

Authors:  Jan M Mühlen; Julie Stang; Esben Lykke Skovgaard; Pedro B Judice; Pablo Molina-Garcia; William Johnston; Luís B Sardinha; Francisco B Ortega; Brian Caulfield; Wilhelm Bloch; Sulin Cheng; Ulf Ekelund; Jan Christian Brønd; Anders Grøntved; Moritz Schumann
Journal:  Br J Sports Med       Date:  2021-01-04       Impact factor: 13.800

Review 4.  Wearable activity trackers-advanced technology or advanced marketing?

Authors:  Ren-Jay Shei; Ian G Holder; Alicia S Oumsang; Brittni A Paris; Hunter L Paris
Journal:  Eur J Appl Physiol       Date:  2022-04-21       Impact factor: 3.346

Review 5.  Accuracy and Precision of Energy Expenditure, Heart Rate, and Steps Measured by Combined-Sensing Fitbits Against Reference Measures: Systematic Review and Meta-analysis.

Authors:  Guillaume Chevance; Natalie M Golaszewski; Elizabeth Tipton; Eric B Hekler; Matthew Buman; Gregory J Welk; Kevin Patrick; Job G Godino
Journal:  JMIR Mhealth Uhealth       Date:  2022-04-13       Impact factor: 4.947

6.  Accuracy of consumer-level and research-grade activity trackers in ambulatory settings in older adults.

Authors:  Salvatore Tedesco; Marco Sica; Andrea Ancillao; Suzanne Timmons; John Barton; Brendan O'Flynn
Journal:  PLoS One       Date:  2019-05-21       Impact factor: 3.240

7.  Wearable health devices and personal area networks: can they improve outcomes in haemodialysis patients?

Authors:  Jeroen P Kooman; Fokko Pieter Wieringa; Maggie Han; Sheetal Chaudhuri; Frank M van der Sande; Len A Usvyat; Peter Kotanko
Journal:  Nephrol Dial Transplant       Date:  2020-03-01       Impact factor: 5.992

8.  Validity of simplified, calibration-less exercise intensity measurement using resting heart rate during sleep: a method-comparison study with respiratory gas analysis.

Authors:  Hirotaka Matsuura; Masahiko Mukaino; Yohei Otaka; Hitoshi Kagaya; Yasushi Aoshima; Takuya Suzuki; Ayaka Inukai; Emi Hattori; Takayuki Ogasawara; Eiichi Saitoh
Journal:  BMC Sports Sci Med Rehabil       Date:  2019-11-04

9.  Assessing the ability of the Fitbit Charge 2 to accurately predict VO2max.

Authors:  Kaitlin A Freeberg; Brett R Baughman; Ted Vickey; Jeff A Sullivan; Brandon J Sawyer
Journal:  Mhealth       Date:  2019-09-23

Review 10.  Sarcopenia in rheumatic disorders: what the radiologist and rheumatologist should know.

Authors:  Wilfred Manzano; Leon Lenchik; Akshay S Chaudhari; Lawrence Yao; Sarthak Gupta; Robert D Boutin
Journal:  Skeletal Radiol       Date:  2021-07-16       Impact factor: 2.199

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.