Literature DB >> 30656704

Influence of static and dynamic cyclic fatigue tests on the lifespan of four reciprocating systems at different temperatures.

A Keleş1, A Eymirli1, O Uyanık1, E Nagas1.   

Abstract

AIM: To compare the cyclic fatigue resistance of four reciprocating single-file systems within artificial stainless-steel canals at two temperatures using different kinematics.
METHODOLOGY: A total of 240 instruments, Reciproc Blue, Reciproc, WaveOne Gold and WaveOne, (60 of each), were tested at room and intracanal temperature using both a static and a dynamic model (n = 15) in a stainless-steel artificial canal with an inner diameter of 1.5 mm, 60° angle of curvature and 5 mm radius of curvature until fracture occurred. The time to fracture was measured in seconds using a digital chronometer, and data were analysed using one-way analysis of variance and Bonferroni tests.
RESULTS: WaveOne instruments had significantly less fatigue resistance compared to that of other systems in all conditions (P < 0.05). Comparison of the results from the static and dynamic models at both temperatures revealed that fatigue resistance was significantly increased in the dynamic model for all the instrument systems (P < 0.05). Temperature did not influence the cyclic fatigue resistance results (P > 0.05). There were no significant differences in the mean length of the fractured fragments of the various instruments tested (P > 0.05).
CONCLUSION: WaveOne files had a shorter cyclic fatigue life. The dynamic axial movement extended the cyclic fatigue life, but it did not have any influence on the comparison among the instruments tested in respect of the static test. Temperature did not significantly affect the cyclic fatigue of these nickel-titanium files.
© 2019 International Endodontic Journal. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  cyclic fatigue; heat treatment; intracanal temperature; static and dynamic tests

Mesh:

Substances:

Year:  2019        PMID: 30656704     DOI: 10.1111/iej.13073

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  8 in total

1.  Comparison of the cyclic fatigue resistance of VDW.ROTATE, TruNatomy, 2Shape, and HyFlex CM nickel-titanium rotary files at body temperature.

Authors:  Mustafa Gündoğar; Gülşah Uslu; Taha Özyürek; Gianluca Plotino
Journal:  Restor Dent Endod       Date:  2020-06-22

2.  Mechanical Properties of the New Generation RACE EVO and R-Motion Nickel-Titanium Instruments.

Authors:  Fatima Betul Basturk; Taha Özyürek; Gülşah Uslu; Mustafa Gündoğar
Journal:  Materials (Basel)       Date:  2022-05-06       Impact factor: 3.748

3.  Differences in cyclic fatigue lifespan between two different heat treated NiTi endodontic rotary instruments: WaveOne Gold vs EdgeOne Fire.

Authors:  Gianluca Gambarini; Massimo Galli; Dario Di Nardo; Marco Seracchiani; Orlando Donfrancesco; Luca Testarelli
Journal:  J Clin Exp Dent       Date:  2019-07-01

4.  Mechanical Properties of ProTaper Gold, EdgeTaper Platinum, Flex Gold and Pro-T Rotary Systems.

Authors:  Murilo Alcalde; Marco Antonio Hungaro Duarte; Pablo Andrés Amoroso Silva; Pedro Henrique Souza Calefi; Emmanuel Silva; Jussaro Duque; Rodrigo Vivan
Journal:  Eur Endod J       Date:  2020-12

5.  Influence of the type of reciprocating motion on the cyclic fatigue resistance of reciprocating files in a dynamic model.

Authors:  Álvaro Zubizarreta-Macho; Alberto Albaladejo Martínez; Carlos Falcão Costa; Norberto Quispe-López; Ruben Agustín-Panadero; Jesús Mena-Álvarez
Journal:  BMC Oral Health       Date:  2021-04-07       Impact factor: 2.757

6.  Multimethod Assessment of the Cyclic Fatigue Strength of ProGlider, Edge Glide Path and R-Pilot Endodontic Instruments.

Authors:  Jorge N R Martins; Duarte Marques; Isabel Vasconcelos; Sofia Arantes-Oliveira; João Caramês; Francisco Manuel Braz Fernandes
Journal:  Dent J (Basel)       Date:  2022-02-17

Review 7.  Effect of body temperature on the cyclic fatigue resistance of the nickel-titanium endodontic instruments: A systematic review and meta-analysis of in vitro studies.

Authors:  Selventhra Savitha; Sidhartha Sharma; Vijay Kumar; Amrita Chawla; Perumal Vanamail; Ajay Logani
Journal:  J Conserv Dent       Date:  2022-08-02

8.  Shot peening increases resistance to cyclic fatigue fracture of endodontic files.

Authors:  Javier Nino-Barrera; Jose Sanchez-Aleman; Manuel Acosta-Humanez; Luis Gamboa-Martinez; Carlos Cortes-Rodriguez
Journal:  Sci Rep       Date:  2021-06-21       Impact factor: 4.379

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.