"Peroperative estimation of bone quality and primary dental implant stability".

Benjamin Voumard1, Ghislain Maquer1, Peter Heuberger2, Philippe K Zysset3, Uwe Wolfram4.   

Abstract

OBJECTIVES: Dental implants are widely used to restore function and appearance. It may be essential to choose the appropriate drilling protocol and implant design in order to optimise primary stability. This could be achieved based on an assessment of the implantation site with respect to bone quality and objective biomechanical descriptors such as stiffness and strength of the bone-implant system. The aim of this ex vivo study is to relate these descriptors with bone quality, with a pre-implantation indicator of implant stability: pilot-hole drilling force (Fdrilling), and with two post-implantation indicators: maximal implantation torque (Timplantation) and resonance frequency analysis (RFA).
METHODS: Eighty trabecular bone specimens were cored from human vertebrae and bovine tibiae. Bone volume fraction (BV/TV), a representative for bone quality, was obtained through micro-computed tomography scans. Implants were kept in controlled laboratory conditions following standard surgical procedures. Forces and torques were recorded and RFA was assessed after implantation. Off-axis compression tests were conducted on the implants until failure. Implant stability was identified by stiffness and ultimate force (Fultimate). The relationships between BV/TV, Stiffness, Fultimate and Fdrilling, Timplantation, RFA were established.
RESULTS: Fdrilling correlated well with BV/TV of the implantation site (r2 = 0.81), stiffness (r2 = 0.75) and Fultimate (r2 = 0.80). Timplantation correlated better with stiffness (r2 = 0.86) and Fultimate (r2 = 0.94) than RFA (r2 = 0.77 and r2 = 0.74, respectively).
CONCLUSION: Our results indicate that BV/TV and bone-implant stability can be directly estimated by the force needed for the pilot drilling that occurs during the site preparation before implantation. Moreover, implantation torque outperforms RFA for evaluating the mechanical competence of the bone-implant system.
Copyright © 2019 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Bone quality; Bone-implant system; Dental implant; Drilling force; Immediate loading; Primary stability

Year:  2018        PMID: 30654217     DOI: 10.1016/j.jmbbm.2018.12.035

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  2 in total

1.  A New Site Preparation Protocol That Supports Bone Quality Evaluation and Provides Predictable Implant Insertion Torque.

Authors:  Stefan Velikov; Cristiano Susin; Peter Heuberger; Ainara Irastorza-Landa
Journal:  J Clin Med       Date:  2020-02-11       Impact factor: 4.241

2.  Peri-implant bone preservation of a novel, self-cutting, and fully tapered implant in the healed crestal ridge of minipigs: submerged vs. transgingival healing.

Authors:  Helena Francisco; Gary Finelle; Fabien Bornert; Rebecca Sandgren; Valentin Herber; Nils Warfving; Benjamin E Pippenger
Journal:  Clin Oral Investig       Date:  2021-05-05       Impact factor: 3.573

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.