| Literature DB >> 30651021 |
Teun Teunis1, Sjoerd Meijer2, Jesse Jupiter3, Daniel Rikli4.
Abstract
This study aimed to determine the association of teardrop angle and anteroposterior distance with anterior lunate facet displacement and articular congruity before and after anterior plating of distal radial fractures. We included 36 patients with complete intra-articular distal radial fractures with separate anterior lunate facet fragments. On radiographs we determined the teardrop angle and anteroposterior distance. On digital three-dimensional models we measured proximal-distal, anteroposterior and ulnoradial anterior lunate facet displacement, and we outlined the gap surface area. Preoperatively, teardrop angle was highly associated with the extent of anterior lunate facet displacement. Increased anteroposterior distance was mainly associated with articular incongruity after anterior plate fixation. This information may reduce the need of preoperative computed tomography scans in fractures with a normal tear drop angle. This is particularly useful in low-resource settings.Entities:
Keywords: Distal radius; anterior lunate facet; anteroposterior distance; teardrop angle
Mesh:
Year: 2019 PMID: 30651021 PMCID: PMC6537136 DOI: 10.1177/1753193418822470
Source DB: PubMed Journal: J Hand Surg Eur Vol ISSN: 0266-7681
Figure 1.Teardrop angle and anteroposterior (A to P) distance.
Figure 2.Reduced and unreduced distal radial fracture model. Right: fractured distal radial with the diaphysis positioned in a template (not shown) to secure similar positioning for all models. Left: fracture fragments reduced into the unfractured template. Blue dotted line: outline of the template’s metaphysis. Right lower corner: template’s orientation: z-axis represents proximal–distal displacement (loss of height), the x-axis radial–ulnar displacement, and the y-axis posteroanterior displacement. Overall, multidirectional (3D) displacement is the factor of those axes.
Figure 3.Gap and step-off measured on sagittal CT with the arc method. A circle is drawn along the curvature of the articular surface of the anterior lunate facet. A line is drawn (marked axis) through the geometric centre of the circle, passing through to the next articular fragment. Step-off is measured between the intersection of the axis and the circle (c) and the bone (b). Gap is measured between the corner of the anterior lunate facet (a) and (c). We selected the CT image with the largest gap and step-off.
Demographics.
| Number of patients | 36 |
|---|---|
| Age (years, mean and range) | 61 (30 to 87) |
| Number of women/men | 21/15 |
| Number of tobacco smokers | 3 |
| Body mass index (kg/m2, mean and range) | 26 (19 to 45) |
| Number of injuries to dominant/nondominant hand | 13/23 |
| Number of styloid fractures | 13 |
| Number of closed reductions | 14 |
Radiographic characteristics.
| Characteristic | Mean (SD) | |
|---|---|---|
| After fracture | After surgery | |
| Teardrop angle (degrees) | 41 (23) | 64 (6.6) |
| Anteroposterior distance (mm) | 21 (3.1) | 20 (3.2) |
| 3D anterior lunate facet fragment displacement (mm) | 3.4 (2.7) | 3.9 (4.3) |
| Proximal-distal displacement (mm) | 1.0 (1.7) | 1.3 (2.6) |
| Posteroanterior displacement (mm) | –0.29 (3.4) | –1.4 (4.4) |
| Ulnoradial displacement (mm) | 0.34 (1.7) | 0.60 (1.9) |
| Surface area of the articular gap (mm2) | 0.88 (0.69) | 0.63 (0.65) |
| CT sagittal step-off (mm) | 1.9 (2.6) | 1.3 (0.91) |
| CT sagittal gap (mm) | 5.7 (3.3) | 4.0 (2.6) |
Pearson correlation between radiographic characteristics and teardrop angle or anteroposterior distance.
| Radiographic characteristics | Pearson correlation (r) between
characteristic and teardrop angle | Pearson correlation (r) between
characteristics and anteroposterior distance | ||||||
|---|---|---|---|---|---|---|---|---|
| After fracture | After surgery | After fracture | After surgery | |||||
| r |
| r |
| r |
| r |
| |
|
| −0.18 | 0.28 | 0.065 | 0.71 | 0.024 | 0.89 | 0.31 | 0.064 |
|
| ||||||||
| Surface area of the anterior lunate facet fragment* | 0.27 | 0.11 | 0.22 | 0.24 | 0.28 | 0.10 | 0.13 | 0.49 |
| Proximal-distal displacement | 0.49 | 0.003 | 0.25 | 0.18 | 0.39 | 0.019 | 0.23 | 0.21 |
| Posterior-anterior displacement | 0.54 | <0.001 | 0.006 | 0.97 | 0.25 | 0.14 | 0.32 | 0.088 |
| Ulnar-radial displacement | –0.19 | 0.26 | –0.021 | 0.91 | –0.19 | 0.27 | –0.22 | 0.23 |
|
| 0.33 | 0.059 | 0.060 | 0.73 | 0.32 | 0.063 | 0.65 | <0.001 |
|
| ||||||||
| CT sagittal step-off | 0.45 | 0.006 | −0.032 | 0.85 | 0.17 | 0.32 | 0.36 | 0.031 |
| CT sagittal gap | 0.26 | 0.13 | 0.0086 | 0.96 | 0.24 | 0.15 | 0.61 | <0.001 |
Bold p-value indicates statistically significant correlation.
Q3DCT: quantitative three dimensional computed tomography.