| Literature DB >> 30646594 |
Qifu Wang1,2, Meng Gao3, Lunjia Zhang4,5, Zhongshan Deng6,7, Lin Gui8.
Abstract
A handy, flexible micro-thermocouple using low-melting-point metal alloys is proposed in this paper. The thermocouple has the advantages of simple fabrication and convenient integration. Bismuth/gallium-based mixed alloys are used as thermocouple materials. To precisely inject the metal alloys to the location of the sensing area, a micro-polydimethylsiloxane post is designed within the sensing area to prevent outflow of the metal alloy to another thermocouple pole during the metal-alloy injection. Experimental results showed that the Seebeck coefficient of this thermocouple reached -10.54 μV/K, which was much higher than the previously reported 0.1 μV/K. The thermocouple was also be bent at 90° more than 200 times without any damage when the mass ratio of the bismuth-based alloy was <60% in the metal-alloy mixture. This technology mitigated the difficulty of depositing traditional thin⁻film thermocouples on soft substrates. Therefore, the thermocouple demonstrated its potential for use in microfluidic chips, which are usually flexible devices.Entities:
Keywords: flexible sensor; liquid metal; low-melting-point alloys; micro-thermocouple
Year: 2019 PMID: 30646594 PMCID: PMC6359204 DOI: 10.3390/s19020314
Source DB: PubMed Journal: Sensors (Basel) ISSN: 1424-8220 Impact factor: 3.576
Figure 1(a) Schematic of the ohm-shape micro-thermocouple; one pole of the channel was filled with EGaInSn, and the other pole of the thermocouple was filled with low-melting-point Bi-based metal–alloy mixture. (b) Zoom in of schematic (a), wherein EGaInSn and the mixture converged at the middle of the channel (sensing area). (c) Local map of the thermocouple chip showing that one pole of the thermocouple channel was filled with the mixture and another pole was filled with EGaInSn. (d) Sketch of bending test. (e) Sketch of temperature-measurement test. A 20 μm-thick polydimethylsiloxane (PDMS) membrane was placed between the thermocouple and the microheater chip.
Figure 2(a) Image of different mass ratios of EBiInSn in mixture. (b) Image of different mass ratios of EBiIn in mixture. With increased mass ratio of bismuth-based alloy, the mixture changes from a liquid to a powdery solid. Scale bars: 1 mm (the experimental mixing videos (S1 and S2) are included in the Supplementary Materials).
Figure 3(a) SEM graphics of EBiInSn-based alloy mixtures. (b) SEM graphics of EBiIn-based alloy mixtures. (c) Energy spectrum diagram of 80% Bi-based alloy mixtures. The element gallium and bismuth were intermingled with each other, filling the entire space. (d) Distribution map of In in 80% EBiInSn. The area in red dashes and the yellow dashes represent the area of Bi and Ga, respectively.
Figure 4(a) Differential scanning calorimetry (DSC) phase diagram of mixture with 50% mass ratio of EBiInSn. (b) DSC phase diagram of mixture with 50% mass ratio of EBiIn.
Figure 5(a) Calibration curve of thermocouples with different ratios of EBiInSn. (b) Calibration curve of thermocouples with different ratios of EBiIn. (c) Seebeck coefficients of thermocouples calculated by the data of the calibration curve. (d) Results of bending test of thermocouples with different ratios of Bi-based alloy (the experimental bending test videos (S3 and S4) are included in the Supplementary Materials).
Figure 6Experimental results of the performance test of thermocouple. The thermocouple with 40% ratio of EBiIn was used to monitor the temperature change of GaInSn microheater.