Literature DB >> 30640749

The Reliability of Intraoperative Crossbar Technique in Determining the Upper Instrumented Vertebra (UIV) Tilt Angle for Adolescent Idiopathic Scoliosis (AIS) Undergoing Posterior Spinal Fusion.

Mun Keong Kwan1, Chee Kidd Chiu1, Saw Huan Goh1, Sherwin Johan Ng1, Pheng Hian Tan1, Xue Han Chian1, Yun Hui Ng1, Xin Yi Ler1, Elrofai Suliman Bashir2, Chris Yin Wei Chan1.   

Abstract

STUDY
DESIGN: Retrospective study.
OBJECTIVE: This study looked into whether crossbar can reliably measure Upper Instrumend Vertebra (UIV) tilt angle intraoperatively and accurately predict the UIV tilt angle postoperatively and at final follow-up. SUMMARY OF BACKGROUND DATA: Postoperative shoulder imbalance is a common cause of poor cosmetic appearance leading to patient dissatisfaction. There were no reports describing the technique or method in measuring the UIV tilt angle intraoperatively. Therefore, this study was designed to look into the reliability and accuracy of the usage of intraoperative crossbar in measuring the UIV tilt angle intraoperatively.
METHODS: Lenke 1 and 2 Adolescent Idiopathic Scoliosis patients who underwent instrumented Posterior Spinal Fusion using pedicle screw constructs with minimum follow-up of 24 months were recruited for this study. After surgical correction, intraoperative UIV tilt angle was measured using a crossbar. Immediate postoperative and final follow up UIV tilt angle was measured on the standing anteroposterior radiographs.
RESULTS: A total of 100 patients were included into this study. The reliability of the intraoperative crossbar to measure the optimal UIV tilt angle intraoperatively was determined by repeated measurements by assessors and measurement by different assessors. We found that the intra observer and inter observer reliability was very good with intraclass correlation coefficient values of >0.9. The accuracy of the intraoperative crossbar to measure the optimal UIV tilt angle intraoperatively was determined by comparing this measurement with the postoperative UIV tilt angle. We found that there was no significant difference (P>0.05) between intraoperative, immediate postoperative, and follow-up UIV tilt angle.
CONCLUSIONS: The crossbar can be used to measure the intraoperative UIV tilt angle consistently and was able to predict the postoperative UIV tilt angle. It was a cheap, simple, reliable, and accurate instrument to measure the intraoperative UIV tilt angle.

Entities:  

Year:  2019        PMID: 30640749     DOI: 10.1097/BSD.0000000000000769

Source DB:  PubMed          Journal:  Clin Spine Surg        ISSN: 2380-0186            Impact factor:   1.876


  1 in total

1.  Feasibility of Single-Stage Posterior Passive Correction and Fusion Surgery for Congenital Scoliosis in Adolescent Patients Who Have Attained Skeletal Maturity.

Authors:  Chee Kidd Chiu; Rommel Lim Tan; Siti Mariam Abd Gani; Jessamine Sze Lynn Chong; Weng Hong Chung; Chris Yin Wei Chan; Mun Keong Kwan
Journal:  Asian Spine J       Date:  2021-05-07
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.