Literature DB >> 30640090

MFC-based biosensor for domestic wastewater COD assessment in constructed wetlands.

C Corbella1, M Hartl1, M Fernandez-Gatell1, J Puigagut2.   

Abstract

In the context of natural-based wastewater treatment technologies (such as constructed wetlands - CW) the use of a low-cost, continuous-like biosensor tool for the assessment of operational conditions is of key importance for plant management optimization. The objective of the present study was to assess the potential use of constructed wetland microbial fuel cells (CW-MFC) as a domestic wastewater COD assessment tool. For the purpose of this work four lab-scale CW-MFCs were set up and fed with pre-settled domestic wastewater at different COD concentrations. Under laboratory conditions two different anodic materials were tested (graphite rods and gravel). Furthermore, a pilot-plant based experiment was also conducted to confirm the findings previously recorded for lab-scale experiments. Results showed that in spite of the low coulombic efficiencies recorded, either gravel or graphite-based anodes were suitable for the purposes of domestic wastewater COD assessment. Significant linear relationships could be stablished between inlet COD concentrations and CW-MFC Ecell whenever contact time was above 10 h. Results also showed that the accuracy of the CW-MFC was greatly compromised after several weeks of operation. Pilot experiments showed that CW-MFC presents a good bio-indication response between week 3 and 7 of operation (equivalent to an accumulated organic loading between 100 and 200 g COD/m2, respectively). Main conclusion of this work is that of CW-MFC could be used as an "alarm-tool" for qualitative continuous influent water quality assessment rather than a precise COD assessment tool due to a loss of precision after several weeks of operation.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Biosensor; Constructed wetlands; Gravel-based anode; Microbial fuel cells; Real wastewater

Mesh:

Substances:

Year:  2018        PMID: 30640090     DOI: 10.1016/j.scitotenv.2018.12.347

Source DB:  PubMed          Journal:  Sci Total Environ        ISSN: 0048-9697            Impact factor:   7.963


  1 in total

1.  Microbial Fuel Cell-Based Biosensor for Simultaneous Test of Sodium Acetate and Glucose in a Mixed Solution.

Authors:  Song Qiu; Luyang Wang; Yimei Zhang; Yingjie Yu
Journal:  Int J Environ Res Public Health       Date:  2022-09-28       Impact factor: 4.614

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.