BACKGROUND: A growing body of research has demonstrated that manual cleaning and disinfection of the operating room (OR) is suboptimal. Residual environmental contamination may pose an infection risk to the surgical wound. This study evaluates the impact of a visible-light continuous environmental disinfection (CED) system on microbial surface contamination and surgical site infections (SSI) in an OR.
METHODS: Samples from 25 surfaces within 2 contiguous ORs sharing an air supply were obtained after manual cleaning on multiple days before and after a visible-light CED system installation in 1 of the ORs. Samples were incubated and enumerated as total colony-forming units. SSIs in both ORs, and a distant OR, were tracked for 1 year prior to and 1 year after the visible-light CED system installation.
RESULTS: There was an 81% (P = .017) and 49% (P = .015) reduction in total colony-forming units after the visible-light CED system installation in the OR in which the system was installed, and in the contiguous OR, respectively. In the OR with the visible-light CED system, SSIs decreased from 1.4% in the year prior to installation to 0.4% following installation (P = .029).
CONCLUSIONS: A visible-light CED system, used in conjunction with manual cleaning, resulted in significant reductions in both microbial surface contamination and SSIs in the OR.
Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Automated disinfection; Environmental disinfection; Surgical site infections; Visible light continuous environmental disinfection; Visible light decontamination

Mesh:

Year:  2019        PMID: 30638672     DOI: 10.1016/j.ajic.2018.12.002

Source DB:  PubMed          Journal:  Am J Infect Control        ISSN: 0196-6553            Impact factor:   2.918


  4 in total

Review 1.  Perioperative Infection Transmission: the Role of the Anesthesia Provider in Infection Control and Healthcare-Associated Infections.

Authors:  Archit Sharma; Patrick G Fernandez; John P Rowlands; Matthew D Koff; Randy W Loftus
Journal:  Curr Anesthesiol Rep       Date:  2020-07-17

2.  Futility of Cluster Designs at Individual Hospitals to Study Surgical Site Infections and Interventions Involving the Installation of Capital Equipment in Operating Rooms.

Authors:  Franklin Dexter; Johannes Ledolter; Richard H Epstein; Randy W Loftus
Journal:  J Med Syst       Date:  2020-03-07       Impact factor: 4.460

3.  Recommendations for change in infection prevention programs and practice.

Authors:  Robert Garcia; Sue Barnes; Roy Boukidjian; Linda Kaye Goss; Maureen Spencer; Edward J Septimus; Marc-Oliver Wright; Shannon Munro; Sara M Reese; Mohamad G Fakih; Charles E Edmiston; Martin Levesque
Journal:  Am J Infect Control       Date:  2022-05-04       Impact factor: 4.303

4.  Sample sizes for surveillance of S. aureus transmission to monitor effectiveness and provide feedback on intraoperative infection control including for COVID-19.

Authors:  Franklin Dexter; Johannes Ledolter; Russell T Wall; Subhradeep Datta; Randy W Loftus
Journal:  Perioper Care Oper Room Manag       Date:  2020-05-21
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.