Literature DB >> 30634170

Measurement of peripheral dose to the pelvic region and the associated risk for cancer development after breast intraoperative electron radiation therapy.

Seyed Rabie Mahdavi1, Mahdieh Tutuni, Bagher Farhood, Nahid Nafisi, Shiva Ghasemi, Hamidreza Mirzaee, Soraya Ahmadi, Ahad Alizadeh.   

Abstract

This study aimed to measure the received dose to the pelvic region of patients during breast intraoperative electron radiation therapy (IOERT). Furthermore, we compared the findings with those of external beam radiation therapy. Finally, secondary ovarian and uterus cancer risks following breast IOERT were estimated. In the current study, the received dose to the pelvic surface of 18 female patients during breast IOERT boosts were measured by thermoluminescent dosimeter (TLD-100) chips. All patients were treated with 12 Gy given in a single fraction. To estimate the dose to the ovary and uterus of the patients, conversion coefficients for depth from the surface dose were obtained in a Rando phantom. Given the received dose to the pelvic region of the patients, secondary ovarian and uterus cancer risks following breast IOERT were estimated. The received doses to the ovary and uterus surface of the patients were 0.260 ± 0.155 mGy to 31.460 ± 6.020 mGy and 0.485 ± 0.122 mGy to 22.387 ± 15.476 mGy, respectively. Corresponding intra-pelvic (ovary and uterus) regional doses were 0.012 ± 0.007 mGy to 1.479 ± 0.283 mGy and 0.027 ± 0.001 mGy to 1.164 ± 0.805 mGy, respectively. Findings demonstrated that the ratio of the received dose by the pelvic surface to the regional dose during breast IOERT was much less than external beam radiation therapy. The mean of the secondary cancer risks for the ovary in 8 and 10 MeV electron beam energies were 135.722 ± 117.331 × 10-6 and 69.958 ± 28.072 × 10-6, and for the uterus were 17.342 ± 10.583 × 10-6 and 2.971 ± 3.604 × 10-6, respectively. According to our findings, the use of breast IOERT in pregnant patients can be considered as a safe radiotherapeutic technique, because the received dose to the fetus was lower than 50 mGy. Furthermore, IOERT can efficiently reduce the unnecessary dose to the pelvic region and lowers the risk of secondary ovarian and uterus cancer following breast irradiation.

Entities:  

Mesh:

Year:  2019        PMID: 30634170     DOI: 10.1088/1361-6498/aafdc8

Source DB:  PubMed          Journal:  J Radiol Prot        ISSN: 0952-4746            Impact factor:   1.394


  1 in total

1.  Verification of electron beam parameters in an intraoperative linear accelerator using dosimetric and radiobiological response methods.

Authors:  Agnieszka Dróżdż; Martyna Waluś; Marcin Zieliński; Bożena Malesa; Marta Kruszyna-Mochalska; Katarzyna Kulcenty; Beata Adamczyk; Piotr Nowaczyk; Julian Malicki; Jacek Pracz
Journal:  Rep Pract Oncol Radiother       Date:  2021-12-30
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.