Literature DB >> 30633788

Evaluation of Different IOL Calculation Formulas of the ASCRS Calculator in Eyes After Corneal Refractive Laser Surgery for Myopia With Multifocal IOL Implantation.

Violette Vrijman, Adi Abulafia, Jan Willem van der Linden, Ivanka J E van der Meulen, Maarten P Mourits, Ruth Lapid-Gortzak.   

Abstract

PURPOSE: To compare the accuracy of different intraocular lens (IOL) calculation formulas available on the American Society of Cataract and Refractive Surgery (ASCRS) post-refractive surgery IOL power calculator for the prediction of multifocal IOL power after previous corneal refractive laser surgery for myopia.
METHODS: An analysis and comparison were performed of the accuracy of three methods using surgically induced change in refraction (ie, Masket, Modified Masket, and Barrett True-K formulas) and three methods using no previous data (ie, Shammas, Haigis-L, and Barrett True-K No History formulas). The average of all formulas was also analyzed and compared.
RESULTS: Thirty-six eyes of 36 patients were included. All formulas, except for the Masket, Modified Masket, and Barrett True-K formulas, had myopic mean numerical errors that were significantly different from zero (P ⩽ .01). The median absolute error of the Shammas formula (0.52 diopters [D]) was significantly higher compared to all of the other formulas (P < .05), except for the Haigis-L formula (P = .09). Comparing the formulas using no previous data, the Barrett True-K No History formula had the lowest median absolute error (0.33 D, P < .001).
CONCLUSIONS: The Shammas formula showed the least accuracy in predicting IOL power in eyes with multifocal IOL implantation after previous corneal refractive laser surgery for myopia. In eyes with all available data, all formulas performed equally except for the Shammas formula, whereas in eyes lacking historical data, the Barrett True-K No History formula performed best. [J Refract Surg. 2019;35(1):54-59.]. Copyright 2019, SLACK Incorporated.

Entities:  

Mesh:

Year:  2019        PMID: 30633788     DOI: 10.3928/1081597X-20181119-01

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  7 in total

1.  Accuracy of intraocular lens power calculation formulae after laser refractive surgery in myopic eyes: a meta-analysis.

Authors:  Hongyu Li; Li Nan; Jun Li; Hui Song
Journal:  Eye Vis (Lond)       Date:  2020-05-01

2.  The repeatability and agreement of biometric measurements by dual Scheimpflug device with integrated optical biometer.

Authors:  Hassan Hashemi; Sara Sardari; Abbasali Yekta; Mehdi Khabazkhoob
Journal:  Sci Rep       Date:  2022-05-11       Impact factor: 4.996

3.  Refractive Precision of Ray Tracing IOL Calculations Based on OCT Data versus Traditional IOL Calculation Formulas Based on Reflectometry in Patients with a History of Laser Vision Correction for Myopia.

Authors:  Bjørn Gjerdrum; Kjell Gunnar Gundersen; Per Olof Lundmark; Bente Monica Aakre
Journal:  Clin Ophthalmol       Date:  2021-02-26

4.  Factors affecting prediction error after cataract surgery with implantation of various multifocal IOLs in patients with previous refractive laser surgery.

Authors:  Young-Sik Yoo; Min Chae Kang; Jongyeop Park; Hyung-Goo Kwon; Eui-Sang Chung; Dong Hui Lim; Tae-Young Chung
Journal:  Ann Transl Med       Date:  2021-12

Review 5.  Intraocular lens power calculations in eyes with previous corneal refractive surgery: Challenges, approaches, and outcomes.

Authors:  Li Wang; Douglas D Koch
Journal:  Taiwan J Ophthalmol       Date:  2021-10-20

6.  Intraocular lens power calculation after two different successive corneal refractive surgeries.

Authors:  Zongsheng Zeng; Xiangyu Ye; Qingzhong Chen; Changkai Jia; Guangbin Zhang
Journal:  Am J Ophthalmol Case Rep       Date:  2022-04-26

7.  Prevalence of Signs and Symptoms of Dry Eye Disease 5 to 15 After Refractive Surgery.

Authors:  Bjørn Gjerdrum; Kjell Gunnar Gundersen; Per Olof Lundmark; Rick Potvin; Bente Monica Aakre
Journal:  Clin Ophthalmol       Date:  2020-01-28
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.