Abstract

In search of the optimal display of echographic information for the detection of focal lesions, a systematic study was performed considering a wide range of gray level transforms (i.e., lookup tables). This range comprised power functions of the echo envelope signal (1/8 less than or equal to n less than or equal to 8), power functions of the logarithmic transform and a sigmoid function. The implications of the transforms on the first order statistics (histogram, "point signal-to-noise ratio" SNRp) and on the second order statistics (autocorrelation function) could be derived both analytically, and from the analysis of simulated and experimentally obtained echograms of homogeneously scattering tissue models. These results were employed to estimate the lesion signal-to-noise ratio SNRl, which specifies the detectability of a lesion by an ideal observer. It was found, both theoretically and practically, that the intensity display corresponds to the optimal transform (i.e., n = 2) for a low contrast lesion. When the data were first logarithmically compressed, the lesion SNR appeared to increase with increasing power (1/8 less than or equal to n less than or equal to 8). A logarithmic transform followed by a sigmoid compression did not produce much improvement. These effects of gray level transforms on the SNRl were shown to be relatively small, with the exception of powers n greater than 2 when applied to linear (i.e. amplitude) data. In the case of high lesion contrast, the sequence of log compression, followed by a square law produced the optimum SNRl. This sequence is equivalent to the processing within echographic equipment, where the TV monitor has a gamma of the order of 2.

Mesh:

Year:  1988        PMID: 3062871     DOI: 10.1177/016173468801000302

Source DB:  PubMed          Journal:  Ultrason Imaging        ISSN: 0161-7346            Impact factor:   1.578


  4 in total

1.  SNR comparisons of beamforming strategies.

Authors:  Jie Liu; Kang-Sik Kim; Michael F Insana
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2007-05       Impact factor: 2.725

2.  Linear System Models for Ultrasonic Imaging: Intensity Signal Statistics.

Authors:  Craig K Abbey; Yang Zhu; Sara Bahramian; Michael F Insana
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2017-01-16       Impact factor: 2.725

3.  Histogram Matching for Visual Ultrasound Image Comparison.

Authors:  Nick Bottenus; Brett C Byram; Dongwoon Hyun
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-04-26       Impact factor: 2.725

4.  CTHRC1 targeted by miR-30a-5p regulates cell adhesion, invasion and migration in lung adenocarcinoma.

Authors:  Chaomian Yang; Tianxia Huang; Yue Liang; Yanlong Xue; Ying Liang; Xianqin Wei; Fangchan Meng; Qiu Wei
Journal:  J Cardiothorac Surg       Date:  2022-03-21       Impact factor: 1.637

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.