Literature DB >> 30627835

Gold nanoparticles conjugated to bimetallic manganese(II) and iron(II) Prussian Blue analogues for aptamer-based impedimetric determination of the human epidermal growth factor receptor-2 and living MCF-7 cells.

Nan Zhou1, Fangfang Su2, Zhenzhen Li2, Xu Yan3, Chunlin Zhang3, Bin Hu2, Linghao He2, Minghua Wang2, Zhihong Zhang4.   

Abstract

An aptamer-based assay is described for the determination of trace levels of the cancer marker human epidermal growth factor receptor-2 (HER2) and living MCF-7 cells. The method is based on the use of a bimetallic MnFe Prussian blue analogue coupled to gold nanoparticles (MnFePBA@AuNP). Compared to pristine MnFe PBA nanocubes, the series of MnFePBA@AuNP exhibits a core-shell spherical nanostructure, and the shell thickness decreases from 99.9 nm down to 49.3 nm on increasing the fraction of AuNPs. The composite was placed on a gold electrode and incubated with the aptamer solution through electrostatic interaction. Then the modified electrode was employed to detect HER2 and MCF-7 cells using [Fe(CN)6]3-/4- as redox probe and displays good responses to both of them. Electrochemical impedance spectroscopy data show that the signal variation between each step during the whole procedure for the HER2 and MCF-7 cells detection can be embodied as the resistance value change between the [Fe(CN)6]3-/4- and electrode surface. The assay has a very low detection limit (0.247 pg∙mL-1) and works in the 0.001-1.0 ng∙mL-1 HER2 concentration range. It was also used to sense HER2 in MCF-7 cells, and this results in an assay that works within the 500-5 × 104 cell∙mL-1 cell concentration range and a 36 cell∙mL-1 detection limit. Furthermore, the aptamer-based assay is selective, acceptably reproducible, stable, and well feasible for the detection of HER2 and living MCF-7 cells in human serum. Graphical abstract Schematic of an electrochemical aptasensor based on the bimetallic MnFe Prussian blue analogue (MnFe PBA) coupling with gold nanoparticles (represented by MnFePBA@AuNPs). It was employed as the aptasensor for human epidermal growth factor receptor-2 (HER2), and living MCF-7 cells.

Entities:  

Keywords:  Au nanoparticles; Cyclic voltammetry; Electrochemical impedance spectroscopy; HER2 detection; Living MCF-7 cell detection; MnFe Prussian blue analogue; Reproducibility; Selectivity; Sensitivity; Stability

Mesh:

Substances:

Year:  2019        PMID: 30627835     DOI: 10.1007/s00604-018-3184-9

Source DB:  PubMed          Journal:  Mikrochim Acta        ISSN: 0026-3672            Impact factor:   5.833


  2 in total

1.  Immunomagnetic bead-based bioassay for the voltammetric analysis of the breast cancer biomarker HER2-ECD and tumour cells using quantum dots as detection labels.

Authors:  Maria Freitas; Henri P A Nouws; Elisa Keating; Virginia Cruz Fernandes; Cristina Delerue-Matos
Journal:  Mikrochim Acta       Date:  2020-02-22       Impact factor: 5.833

2.  Quantification of EGFR and EGFR-overexpressed cancer cells based on carbon dots@bimetallic CuCo Prussian blue analogue.

Authors:  Yingpan Song; Lina He; Kun Chen; Minghua Wang; Longyu Yang; Linghao He; Chuanpan Guo; Qiaojuan Jia; Zhihong Zhang
Journal:  RSC Adv       Date:  2020-07-29       Impact factor: 4.036

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.