Literature DB >> 30625430

Percentile-specific computational phantoms constructed from ICRP mesh-type reference computational phantoms (MRCPs).

Hanjin Lee1, Yeon Soo Yeom, Thang Tat Nguyen, Chansoo Choi, Haegin Han, Bangho Shin, Xujia Zhang, Chan Hyeong Kim, Beom Sun Chung, Maria Zankl.   

Abstract

Recently, the Task Group 103 of the International Commission on Radiological Protection (ICRP) has developed new mesh-type reference computational phantoms (MRCPs) for adult male and female. When compared to the current voxel-type reference computational phantoms in ICRP Publication 110, the MRCPs have several advantages, including deformability which makes it possible to create phantoms in different body sizes or postures. In the present study, the MRCPs were deformed to produce a set of percentile-specific phantoms representing the 10th, 50th and 90th percentiles of standing height and body weight in Caucasian population. For this, anthropometric parameters for the percentile-specific phantoms were first derived from the anthropometric software and survey data. Then, the MRCPs were modified to match the derived anthropometric parameters. For this, first, the MRCPs were scaled in the axial direction to match the head height, torso length, and leg length. Then, the head, torso, and legs were scaled in the transversal directions to match the lean body mass for the percentile-specific phantoms. Finally, the scaled phantoms were manually adjusted to match the body weight and the remaining anthropometric parameters (upper arm, waist, buttock, thigh, and calf circumferences and sagittal abdominal diameter). The constructed percentile-specific phantoms and the MRCPs were implemented into the Geant4 Monte Carlo code to calculate organ doses for a cesium-137 contaminated floor. The results showed that organ doses of the 50th percentile (both standing height and body weight) phantoms are very close to those of the MRCPs. There were noticeable differences in organ doses, however, for the 10th and 90th percentile phantoms when compared with those of the MRCPs. The results of the present study confirm the general intuition that a small person receives higher doses than a large person when exposed to a static radiation field, and organs closer to the source receive higher doses.

Entities:  

Year:  2019        PMID: 30625430     DOI: 10.1088/1361-6560/aafcdb

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  PARaDIM: A PHITS-Based Monte Carlo Tool for Internal Dosimetry with Tetrahedral Mesh Computational Phantoms.

Authors:  Lukas M Carter; Troy M Crawford; Tatsuhiko Sato; Takuya Furuta; Chansoo Choi; Chan Hyeong Kim; Justin L Brown; Wesley E Bolch; Pat B Zanzonico; Jason S Lewis
Journal:  J Nucl Med       Date:  2019-06-14       Impact factor: 10.057

2.  Dose coefficients of percentile-specific computational phantoms for photon external exposures.

Authors:  Yeon Soo Yeom; Haegin Han; Chansoo Choi; Bangho Shin; Chan Hyeong Kim; Choonsik Lee
Journal:  Radiat Environ Biophys       Date:  2019-11-02       Impact factor: 1.925

3.  Technical Note: Patient-morphed mesh-type phantoms to support personalized nuclear medicine dosimetry - a proof of concept study.

Authors:  Jason S Lewis; Adam L Kesner; Lukas M Carter; Juan Camilo Ocampo Ramos; Wesley E Bolch
Journal:  Med Phys       Date:  2021-03-09       Impact factor: 4.071

4.  Patient Size-Dependent Dosimetry Methodology Applied to 18F-FDG Using New ICRP Mesh Phantoms.

Authors:  Lukas M Carter; Chansoo Choi; Simone Krebs; Bradley Jay Beattie; Chan Hyeong Kim; Heiko Schoder; Wesley E Bolch; Adam Leon Kesner
Journal:  J Nucl Med       Date:  2021-04-16       Impact factor: 11.082

5.  Development of a novel program for conversion from tetrahedral-mesh-based phantoms to DICOM dataset for radiation treatment planning: TET2DICOM.

Authors:  Bo-Wi Cheon; Se Hyung Lee; Min Cheol Han; Chul Hee Min; Haegin Han; Chan Hyeong Kim; Jin Sung Kim
Journal:  J Appl Clin Med Phys       Date:  2021-10-11       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.