Literature DB >> 30624832

Zirconia Primers Improve the Shear Bond Strength of Dental Zirconia.

René Steiner1, Irene Heiss-Kisielewsky1, Vincent Schwarz1, Dagmar Schnabl1, Herbert Dumfahrt1, Johannes Laimer2, Otto Steinmassl2, Patricia-Anca Steinmassl1.   

Abstract

PURPOSE: Various resin cements and priming agents are available for adhesive luting of zirconia restorations. The purpose of this study was to investigate how cement type and priming protocol affect the shear bond strength on zirconia ceramics.
MATERIALS AND METHODS: Yttria-stabilized tetragonal zirconia polycrystalline ceramic cylinders were bonded to flat zirconia ceramic surfaces using 7 commercially available resin cements. Ten specimens of each cement group were pretreated with a universal primer, and 10 specimens per group were bonded without pretreatment. In addition, 10 specimens per group were pretreated with system-specific zirconia primers, which were available for 3 cements. Altogether, 170 bonded specimens were water-stored, thermal-cycled, and then submitted to shear bond strength tests. The shear bond strength and the fracture types were documented. Differences in shear bond strengths were assessed using 2-way ANOVA with post-hoc test (α = 0.05). A point-biserial correlation was run between the fracture patterns and the shear bond strengths.
RESULTS: The mean shear bond strengths of cements in the unprimed group showed large variations between 2.52 ± 3.01 (mean ± SD) MPa and 33.15 ± 7.35 MPa. Pretreating the specimens with a universal primer improved the shear bond strengths significantly in all groups (p < 0.05) with a range of 21.80 ± 12.51 to 57.20 ± 11.40 MPa. The system-specific primers also improved the shear bond strength significantly, compared to the unprimed group (p < 0.01); however, only one system-specific primer achieved a shear bond strength superior to the universal primer (p < 0.01). There was also a statistical correlation between the fracture type and the shear bond strength (p < 0.0005), with cohesively fractured specimens showing higher shear bond strengths (37.24 ± 19.87 MPa) than adhesively fractured specimens (23.10 ± 17.65 MPa) (p < 0.001).
CONCLUSION: Using universal primer can enhance the maximal shear bond strength of zirconia.
© 2019 by the American College of Prosthodontists.

Entities:  

Keywords:  Airborne particle abrasion; MDP; cohesive fracture; surface conditioning

Year:  2019        PMID: 30624832     DOI: 10.1111/jopr.13013

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  3 in total

Review 1.  Do tooth-supported zirconia restorations present more technical failures related to fracture or loss of retention? Systematic review and meta-analysis.

Authors:  Carla Castiglia Gonzaga; Paula Pontes Garcia; Letícia Maíra Wambier; Fernanda Harumi Oku Prochnow; Luciano Madeira; Paulo Francisco Cesar
Journal:  Clin Oral Investig       Date:  2022-06-04       Impact factor: 3.606

2.  Retention strength of monolithic zirconia crowns cemented with different primer-cement systems.

Authors:  Mohamed Shokry; Walid Al-Zordk; Mohamed Ghazy
Journal:  BMC Oral Health       Date:  2022-05-19       Impact factor: 3.747

3.  Effects of 10-MDP Based Primer on Shear Bond Strength between Zirconia and New Experimental Resin Cement.

Authors:  Francesco Valente; Luan Mavriqi; Tonino Traini
Journal:  Materials (Basel)       Date:  2020-01-05       Impact factor: 3.623

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.