Literature DB >> 30624127

Appropriate Needle Length for Emergent Pediatric Needle Thoracostomy Utilizing Computed Tomography.

Maria J Mandt, Kari Hayes, Fred Severyn, Kathleen Adelgais.   

Abstract

Objective: Needle thoracostomy is a life-saving procedure. Advanced Trauma Life Support guidelines recommend insertion of a 5 cm, 14-gauge needle for pneumothorax decompression. High-risk complications can arise if utilizing an inappropriate needle size. No study exist evaluating appropriate needle length in pediatric patients. Utilizing computed tomography (CT), we determined the needle length required to access the pleural cavity in children matched to Broselow™ Pediatric Emergency Tape color.
Methods: Three investigators reviewed chest CTs of children <13 years of age obtained between 2010 and 2015. Patient exclusions included those with a chest wall mass, muscle disease, pectus deformity, anasarca, prior open thoracotomy, inadequate imaging, or missing height documentation. We established 4 groups based upon Broselow™ color as determined by recorded height. Investigators, trained by a pediatric board-certified radiologist, obtained standardized CT measurements of chest wall thickness at 4 points: right/left second intercostal space at the midclavicular line (ICS-MCL) and right/left fourth intercostal space in the anterior axillary line (ICS-AAL). Our outcome was the median chest wall thickness and 95% confidence intervals for each Broselow grouping and anatomic site.
Results: A total of 273 chest CTs were reviewed, of which 23 were excluded, for a resultant study population of 250 scans and 498 total measurements. Median patient age was 4 years, 52.8% were male. Children measuring Broselow Gray/Pink (<68 cm), had a median chest wall thickness at the 2nd ICS-MCL of 1.57 cm (95% CI 1.42 cm, 1.72 cm), 4th ICS-AAL 1.67 cm (95% CI 1.48 cm, 1.86 cm). Broselow Red/Purple (68.1-90 cm): 2nd ICS-MCL of 1.96 cm (95% CI 1.84 cm, 2.08 cm), 4th ICS-AAL 1.73 cm (95% CI 1.62 cm, 1.84 cm). Broselow Yellow/White (90.1-115cm): 2nd ICS-MCL of 2.12 cm (95% CI 2.03 cm, 1.22 cm), 4th ICS-AAL 1.91 cm (95% CI 1.8 cm, 2.01 cm). Broselow Blue/Orange/Green (>115.1 cm): 2nd ICS-MCL of 2.45 cm (95% CI 2.3 cm, 2.6 cm), 4th ICS-AAL 2.19cm (95% CI 2.02 cm, 2.36 cm).
Conclusion: Median chest wall thickness varies little by height or location in children <13 years of age. The standard 5-cm needle is twice the chest wall thickness of most children. Commercially available 14 g or 16 g standard-length 3.8 cm (1½ inch) needles are of adequate length to access the pleural cavity, regardless of height as measured by Broselow LBT.

Entities:  

Keywords:  needle thoracostomy; pediatric; emergent; needle size; Broselow

Mesh:

Year:  2019        PMID: 30624127     DOI: 10.1080/10903127.2019.1566422

Source DB:  PubMed          Journal:  Prehosp Emerg Care        ISSN: 1090-3127            Impact factor:   3.077


  2 in total

1.  Sonographic assessment of pediatric chest wall thickness and width of the intercostal space: correlation with anthropometric data and implications for needle decompression.

Authors:  Tom Terboven; Ivette Betka; Christel Weiss; Marcus Rudolph; Tim Viergutz; Georg Leonhard; Michael Schöler
Journal:  Ultrasound J       Date:  2021-05-10

2.  Determining optimal needle size for decompression of tension pneumothorax in children - a CT-based study.

Authors:  Georg Leonhard; Daniel Overhoff; Lucas Wessel; Tim Viergutz; Marcus Rudolph; Michael Schöler; Holger Haubenreisser; Tom Terboven
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2019-10-11       Impact factor: 2.953

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.