Literature DB >> 30612640

Evaluation of different competitive immunoassays for aflatoxin M1 determination in milk samples by means of inductively coupled plasma mass spectrometry.

Emma Pérez1, Francisco M Marco2, Pascual Martínez-Peinado2, Juan Mora1, Guillermo Grindlay3.   

Abstract

Haptens (i.e. biomolecules which molecular weight is lower than 10 kDa) determination by inductively coupled plasma mass spectrometry (ICP-MS) is usually performed by means of competitive immunoassays. In these immunoassays, analyte quantification is indirectly carried out using two different tracer species (i.e. antibodies or antigen-protein conjugates). However, the benefits (and drawbacks) derived from using a given tracer species have not been systematically investigated so far. The goal of this work is to evaluate the influence of the tracer species employed in competitive immunoassays on the analytical figures of merit for aflatoxin M1 (AFM1) determination in milk samples. To this end, three different strategies have been developed and evaluated, namely: (i) antibody binding inhibition assay (ABIA); (ii) capture inhibition assay (CIA); and (iii) capture bridge inhibition assay (CBIA). Experimental results show that the use of the antibody as tracer species (as in the ABIA approach) affords better analytical figures of merit for AFM1 determination than using the antigen-protein conjugate as the tracer one (as in the CIA and CBIA strategies). The limit of detection afforded by ABIA strategy (i.e. 0.1 ng kg-1) for AFM1 determination was 1000-fold and 50-fold lower regarding the CIA and CBIA strategies, respectively. In the case of the ABIA approach, the characteristics of the metal nanoparticle label employed to detect the tracer species is critical on the analytical figures of merit. However, when the hapten-protein conjugates are used as tracer species, immunocomplex formation is severely hampered by steric effects caused by the protein moiety and, consequently, the characteristics of the metal nanoparticle label is not critical in the immunoassay performance. The different immunoassay strategies were successfully validated for AFM1 determination in milk samples using a certified reference material of whole milk powder (ERM-BD283) according to European Conformity guidelines for analytical methods of food contaminants and mycotoxins. Compared to ELISA, the immunoassay developed for AFM1 determination in milk samples improve limits of detection up to 10-fold.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Aflatoxin M(1); Competitive immunoassay; Hapten; Inductively coupled plasma mass spectrometry; Nanoparticle

Mesh:

Substances:

Year:  2018        PMID: 30612640     DOI: 10.1016/j.aca.2018.11.024

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  2 in total

1.  Development and Validation of an Automated Magneto-Controlled Pretreatment for Chromatography-Free Detection of Aflatoxin B1 in Cereals and Oils through Atomic Absorption Spectroscopy.

Authors:  Jin Ye; Mengyao Zheng; Haihua Ma; Zhihong Xuan; Wei Tian; Hongmei Liu; Songxue Wang; Yuan Zhang
Journal:  Toxins (Basel)       Date:  2022-07-01       Impact factor: 5.075

2.  Signal amplification strategies for clinical biomarker quantification using elemental mass spectrometry.

Authors:  Andrea L Larraga-Urdaz; Maria L Fernandez Sanchez; Jorge Ruiz Encinar; Jose M Costa-Fernandez
Journal:  Anal Bioanal Chem       Date:  2021-03-05       Impact factor: 4.142

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.