Literature DB >> 30612069

Impact of prone positioning in infants with Pierre Robin sequence: a polysomnography study.

L Coutier1, A Guyon2, P Reix3, P Franco4.   

Abstract

OBJECTIVE/
BACKGROUND: Obstructive sleep apnea syndrome (OSA) is frequent in Pierre Robin sequence (PRS) infants. Prone positioning (PP) is commonly recommended but has never been studied by polysomnography (PSG). This study aimed to evaluate the impact of the PP on sleep and breathing outcomes measured by PSG. PATIENTS/
METHODS: Retrospective study conducted between 2015 and 2017 in a tertiary hospital. A PSG with pulse oximetry and transcutaneous carbon dioxide was performed in PRS infants in the supine position (SP) and the PP. Sleep and breathing outcome measures were compared between SP and PP.
RESULTS: Among the 18 PRS (mean ± SD age: 44 ± 26 days at evaluation), 11 had clinical manifestations of OSA. All had severe OSA diagnosed on PSG. In the PP, infants had a significantly higher sleep efficiency (median [IQR]: 83% [69-90]) than in the SP (70% [55-77], p = 0.04). During REM, there was a trend towards lower OAHI in the PP (50/h [28-82] versus 61/h [40-103], p = 0.05). For 13, the PP was the best sleep position (72%), and for four the SP was the best sleep position (22%; p < 0.01). The PP was sufficient alone to decrease OSA index <10 events/hour in three infants.
CONCLUSION: Positioning infants in the PP led to an improvement of sleep quality and an incomplete correction of OSAS in the vast majority of PRS infants. A nocturnal sleep recording seems to be indicated systematically in the early evaluation of these young patients to choose the best therapeutic option for OSAS. CLINICAL TRIAL REGISTRATION: Not applicable.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Infants; Pediatric; Pierre Robin sequence; Polysomnography; Prone positioning; Sleep

Mesh:

Year:  2018        PMID: 30612069     DOI: 10.1016/j.sleep.2018.10.037

Source DB:  PubMed          Journal:  Sleep Med        ISSN: 1389-9457            Impact factor:   3.492


  3 in total

1.  Understanding the Spectrum of Treatment Options for Infants With Pierre Robin Sequence and Airway Obstruction.

Authors:  Joanna E MacLean
Journal:  J Clin Sleep Med       Date:  2019-03-15       Impact factor: 4.062

2.  Objective measurements for upper airway obstruction in infants with Robin sequence: what are we measuring? A systematic review.

Authors:  Robrecht J H Logjes; Joanna E MacLean; Noor W de Cort; Christian F Poets; Véronique Abadie; Koen F M Joosten; Cory M Resnick; Ivy K Trindade-Suedam; Carlton J Zdanski; Christopher R Forrest; Frea H Kruisinga; Roberto L Flores; Kelly N Evans; Corstiaan C Breugem
Journal:  J Clin Sleep Med       Date:  2021-08-01       Impact factor: 4.324

Review 3.  Obstructive Sleep Apnea in Neonates.

Authors:  Indira Chandrasekar; Mary Anne Tablizo; Manisha Witmans; Jose Maria Cruz; Marcus Cummins; Wendy Estrellado-Cruz
Journal:  Children (Basel)       Date:  2022-03-15
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.