Mobilized peripheral blood stem cell apheresis via Hickman catheter in pediatric patients.

Nora Doberschuetz1, Jan Soerensen1, Halvard Bonig2,3, Andre Willasch1, Eva Rettinger1, Verena Pfirrmann1, Emilia Salzmann-Manrique1, Richard Schäfer3, Thomas Klingebiel1, Peter Bader1, Andrea Jarisch1.   

Abstract

BACKGROUND: Autologous stem cell transplantation remains an integral treatment tool for certain childhood malignancies. In children, a central venous catheter is typically necessary to provide adequate flow rates for preparative apheresis. In this study, the feasibility and efficiency of collecting CD34+ cells via an indwelling Hickman catheter, preimplanted for chemotherapy, instead of placing an additional temporary central venous catheter was evaluated. STUDY DESIGN AND METHODS: Forty-eight pediatric leukaphereses for autologous hematopoietic stem cell transplantation using Spectra Optia MNC, Version 3.0 were reviewed. We compared preimplanted Hickman catheters with a temporary Shaldon catheter, inserted for apheresis. Apheresis was considered successful if a dose of 2 × 106 CD34+ peripheral blood stem cells/kg BW was achieved.
RESULTS: In 43 (89.6%) of the 48 patients, a Hickman catheter was used for leukapheresis. Only 5 patients (10.4%) received a temporary Shaldon catheter. In both groups, apheresis was performed without apparent adverse reactions. The dose of collected CD34+ peripheral blood stem cells was 12.7 × 106 (range, 2.3-70.7 × 106 ) cells/kg BW in the Hickman group and 16.2 × 106 (range, 3.8-48.4 × 106 ) cells/kg BW in the Shaldon group, showing no statistically significant difference (p = 0.58). In both groups, the primary endpoint of a minimal CD34+ cell concentration of 2 × 106 cells/kg BW was achieved at a maximum of two leukapheresis sessions. Apheresis efficacy was further confirmed by the collection efficiency of 40.2% in the Hickman group and 27.8% in the Shaldon group (p = 0.32).
CONCLUSION: These data indicate the reliable feasibility and efficacy of mobilized apheresis via an indwelling Hickman catheter. In light of this, the routine insertion of a dialysis catheter for the purpose of leukapheresis should be critically reconsidered.
© 2019 AABB.

Entities:  

Mesh:

Year:  2019        PMID: 30610749     DOI: 10.1111/trf.15113

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  1 in total

1.  A high-throughput microfluidic device based on controlled incremental filtration to enable centrifugation-free, low extracorporeal volume leukapheresis.

Authors:  Dalia L Lezzar; Fong W Lam; Ravin Huerta; Anton Mukhamedshin; Madeleine Lu; Sergey S Shevkoplyas
Journal:  Sci Rep       Date:  2022-08-13       Impact factor: 4.996

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.