Literature DB >> 30609544

Redox titration on foldable paper-based analytical devices for the visual determination of alcohol content in whiskey samples.

Sandro A Nogueira1, Adriano D Lemes2, Adriana C Chagas2, Maurício L Vieira3, Márcio Talhavini3, Pedro A O Morais1, Wendell K T Coltro4.   

Abstract

This report describes the development of foldable paper-based analytical devices (PADs) to perform redox titrations. Paper devices were designed to contain three spot tests, which were wax printed and folded to create a three-layer structured platform and to promote the sample transport based on vertical flow. The proposed devices were explored for the visual determination of the alcoholic content in whiskey samples. For this purpose, a classical permanganometry reaction was employed to allow the indirect determination of ethanol based on the required amount of oxalic acid to react with the excess of permanganate in acidic medium. The endpoint of the redox titrations performed in different alcoholic concentrations was measured and revealed a good linear behavior for the ethanol concentration range between 0% and 50% (R2 = 0.992), achieving a limit of detection equal to 2.1%. The alcoholic content was determined in a total of 44 whiskey samples seized by the Brazilian Federal Police. When compared to genuine samples and using an established cut-off limit, 73% of the seized samples were correctly classified as whiskeys containing adulterated alcoholic content. The proposed method was compared to a reference protocol and no difference was observed at the confidence level of 95%. The instrumental simplicity, the low cost, the sample volume requirement, the short analysis time and mainly the inherent portability make these devices quite attractive for on-site forensic applications.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Alcoholic beverages; Crime scene; Food control; Forensic chemistry; Paper microfluidics; Point-of-need

Year:  2018        PMID: 30609544     DOI: 10.1016/j.talanta.2018.10.036

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Modification of Microfluidic Paper-Based Devices with an Oxidant Layer for Distance Readout of Reducing Substances.

Authors:  Chunxiu Xu; Guoxing Zhou; Huihui Cai; Yicong Chen; Ling Huang; Longfei Cai; Jiaye Gong; Zankai Yan
Journal:  ACS Omega       Date:  2022-06-02

2.  A convenient detection system consisting of efficient Au@PtRu nanozymes and alcohol oxidase for highly sensitive alcohol biosensing.

Authors:  Feng Lv; Yuzhu Gong; Yingying Cao; Yaoyao Deng; Shufeng Liang; Xin Tian; Hongwei Gu; Jun-Jie Yin
Journal:  Nanoscale Adv       Date:  2020-02-27

3.  A low cost smart system to analyze different types of edible Bird's nest adulteration based on colorimetric sensor array.

Authors:  Xiaowei Huang; Zhihua Li; Xiaobo Zou; Jiyong Shi; Haroon Elrasheid Tahir; Yiwei Xu; Xiaodong Zhai; Xuetao Hu
Journal:  J Food Drug Anal       Date:  2019-07-16       Impact factor: 6.157

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.