The modified ablation index: a novel determinant of acute pulmonary vein reconnections after pulmonary vein isolation.

Yuji Wakamatsu1, Koichi Nagashima2, Ichiro Watanabe1, Ryuta Watanabe1, Masaru Arai1, Naoto Otsuka1, Seina Yagyu1, Sayaka Kurokawa1, Kimie Ohkubo1, Toshiko Nakai1, Yasuo Okumura1.   

Abstract

BACKGROUND: Although pulmonary vein isolation (PVI) guided by the ablation index (AI) has been well-developed, acute PV reconnections (PVRs) still occur. This study aimed to compare the prognostic performance of the modified AI and its optimal cut-off value for the prediction of acute PVRs to ensure durable PVI.
METHODS: Three-dimensional left atrium (LA) voltage maps created before an extensive encircling PVI in 64 patients with atrial fibrillation (AF) (45 men, 62 ± 10 years) were examined for an association between electrogram voltage amplitude recorded from the PV-LA junction and acute post-PVI PVRs (spontaneous PVRs and/or ATP-provoked dormant PV conduction).
RESULTS: Acute PVRs were observed in 22 patients (34%) and 33 (3%) of the 1012 PV segments. Acute PVRs were significantly associated with segments with higher bipolar voltage zones (3.23 ± 1.17 vs. 1.97 ± 1.20 mV, P < 0.0001), lower mean AI values (449 [428-450] vs. 460 [437-486], P = 0.05), and radiofrequency lesion gaps ≥ 6 mm (48 vs. 32%, P = 0.04), but not with contact force, force-time integral, or power. We created the modified AI calculated as AI/LA bipolar voltage, and found it to be significantly lower in areas with acute PVRs than in those without (152 [109-185] vs. 256 [176-413] AU/mV, P < 0.0001). Univariate analysis showed the prognostic performance of the modified AI, with an area under the curve of 0.801 (0.775-0.825), to be the highest of all the significant parameters.
CONCLUSIONS: Low values of the novel modified AI on the PV-encircling ablation line were strongly associated with acute PVRs.

Entities:  

Keywords:  Ablation index; Atrial fibrillation; Catheter ablation; Force–time integral; High-voltage zone; Pulmonary vein isolation

Year:  2019        PMID: 30607666     DOI: 10.1007/s10840-018-0501-5

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  1 in total

1.  Performance of the ablation index during pulmonary vein isolation: periprocedural data from a multicenter registry.

Authors:  Nigar Z Gasimova; Anatoly A Nechepurenko; Evgeny B Kropotkin; Eduard A Ivanitsky; Grigorii V Kolunin; Dmitry A Shavshin; Bor Antolic; Elena A Artyukhina; Ayan S Abdrakhmanov; Konstantin S Korolev; Dmitry S Lebedev; Evgeny N Mikhaylov
Journal:  J Interv Card Electrophysiol       Date:  2022-05-16       Impact factor: 1.759