Literature DB >> 30598308

Accuracy of 4 digital scanning systems on prepared teeth digitally isolated from a complete dental arch.

Priscilla Medina-Sotomayor1, Agustín Pascual-Moscardo2, Isabel Camps A3.   

Abstract

STATEMENT OF PROBLEM: The accuracy of digital scanners is acceptable for scanning a complete dental arch. However, whether that accuracy is sufficient for only 1 tooth within the dental scan of a complete dental arch is unclear.
PURPOSE: The purpose of this in vitro study was to evaluate and compare the accuracy of 4 intraoral scanners on a complete dental arch and on prepared teeth digitally isolated from the digital scan in terms of trueness and precision.
MATERIAL AND METHODS: A model of a complete dental arch with tooth preparations was scanned 40 times with each of the 4 digital scanners. Their accuracy was evaluated by using 3-dimensional (3D) software to compare the test models with a highly accurate reference model. The data were digitally processed to isolate the prepared teeth and evaluate them in the same way. The data were statistically analyzed using the Levene test and the Tamhane's T2 test (α=.05).
RESULTS: In scans of a complete dental arch, the True Definition scanner had the best accuracy values, followed by TRIOS, iTero, and Omnicam. For prepared teeth isolated from the dental arch, both True Definition and TRIOS had the best values, followed by iTero and Omnicam.
CONCLUSIONS: In both long-span scans of the complete dental arch and isolated prepared teeth, the True Definition scanner had the greatest accuracy, closely followed by TRIOS.
Copyright © 2018 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Mesh:

Year:  2018        PMID: 30598308     DOI: 10.1016/j.prosdent.2018.08.020

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  10 in total

1.  Digital intraoral scanner devices: a validation study based on common evaluation criteria.

Authors:  Ivett Róth; Alexandra Czigola; Dóra Fehér; Viktória Vitai; Gellért Levente Joós-Kovács; Péter Hermann; Judit Borbély; Bálint Vecsei
Journal:  BMC Oral Health       Date:  2022-04-26       Impact factor: 3.747

2.  A New Approach to Accuracy Evaluation of Single-Tooth Abutment Using Two-Dimensional Analysis in Two Intraoral Scanners.

Authors:  Jiyoun Maeng; Young-Jun Lim; Bongju Kim; Myung-Joo Kim; Ho-Beom Kwon
Journal:  Int J Environ Res Public Health       Date:  2019-03-20       Impact factor: 3.390

3.  Accuracy evaluation of 3D printed interim prosthesis fabrication using a CBCT scanning based digital model.

Authors:  Young Hyun Kim; Bock-Young Jung; Sang-Sun Han; Chang-Woo Woo
Journal:  PLoS One       Date:  2020-10-16       Impact factor: 3.240

4.  Effect of the volumetric dimensions of a complete arch on the accuracy of scanners.

Authors:  Min-Kyu Kim; KeunBaDa Son; Beom-Young Yu; Kyu-Bok Lee
Journal:  J Adv Prosthodont       Date:  2020-12-28       Impact factor: 1.904

5.  Influence of Static Navigation Technique on the Accuracy of Autotransplanted Teeth in Surgically Created Sockets.

Authors:  Elena Riad Deglow; Nayra Zurima Lazo Torres; David Gutiérrez Muñoz; María Bufalá Pérez; Agustín Galparsoro Catalán; Álvaro Zubizarreta-Macho; Francesc Abella Sans; Sofía Hernández Montero
Journal:  J Clin Med       Date:  2022-02-15       Impact factor: 4.241

6.  Quantitative and qualitative evaluation on the accuracy of three intraoral scanners for human identification in forensic odontology.

Authors:  Eun-Jeong Bae; Eun-Jin Woo
Journal:  Anat Cell Biol       Date:  2022-03-31

7.  In vitro comparative analysis of scanning accuracy of intraoral and laboratory scanners in measuring the distance between multiple implants.

Authors:  Reiji Natsubori; Shota Fukazawa; Toyokazu Chiba; Norimasa Tanabe; Hidemichi Kihara; Hisatomo Kondo
Journal:  Int J Implant Dent       Date:  2022-04-13

8.  Effect of Tooth Types on the Accuracy of Dental 3D Scanners: An In Vitro Study.

Authors:  Keunbada Son; Kyu-Bok Lee
Journal:  Materials (Basel)       Date:  2020-04-09       Impact factor: 3.623

9.  Novel Digital Technique to Quantify the Area and Volume of Cement Remaining and Enamel Removed after Fixed Multibracket Appliance Therapy Debonding: An In Vitro Study.

Authors:  Álvaro Zubizarreta-Macho; Martina Triduo; Jorge Alonso Pérez-Barquero; Clara Guinot Barona; Alberto Albaladejo Martínez
Journal:  J Clin Med       Date:  2020-04-12       Impact factor: 4.241

10.  A Comparison of Full Arch Trueness and Precision of Nine Intra-Oral Digital Scanners and Four Lab Digital Scanners.

Authors:  Adam B Nulty
Journal:  Dent J (Basel)       Date:  2021-06-23
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.