Literature DB >> 30597629

Intravasation Affects the Diagnostic Image Quality of Transvaginal 4-Dimensional Hysterosalpingo-Contrast Sonography With SonoVue.

Yanni He1,2, Haorong Wu2, Ran Xiong2, Hongmei Liu1,2, Jiayao Shi1,2, Jingjiao Xu2, Ning Zhang1,2, Yu Liu1,2.   

Abstract

OBJECTIVES: We aim to retrospectively analyze the diagnostic image quality of transvaginal 4-dimensional hysterosalpingo-contrast sonography from infertile patients and determine the significant influencing factors.
METHODS: A total of 445 patients visiting infertility clinics were included in the study, of which 167 were primary infertile and 278 were secondary infertile. The factors were recorded, including age; examination time; infertility type; history of pelvic inflammatory disease, pelvic surgery, intrauterine surgery, and ectopic pregnancy; endometrial thickness; uterine position; ovarian position; 2-dimensional image quality; intravasation quantity, position, and time; balloon volume; and the dosage of contrast agent or the sterile saline solution. All the factors were compared among different diagnostic image quality groups. The method of rank logistic regression analysis was adopted to analyze the risk factors affecting the diagnostic image quality.
RESULTS: Among the 445 infertile patients, 124 (27.9%) patients had intravasation occur during transvaginal 4-dimensional hysterosalpingo-contrast sonography. The diagnostic image quality between the 2 sonographers was consistent (Cronbach's alpha, 0.993). Different intravasation quantities, positions, and times; increased of balloon volume; and history of pelvic surgery were substantial risk factors for the diagnostic image quality. The diagnostic image quality diminished with the increase of intravasation. In the patient with cornual intravasation, the diagnostic image quality was substantially worse than that with non-cornual intravasation. Moreover, early onset of intravasation seriously affected the diagnostic image quality.
CONCLUSIONS: In conclusion, intravasation affected the diagnostic image quality, especially early cornual massive intravasation.
© 2018 by the American Institute of Ultrasound in Medicine.

Entities:  

Keywords:  fallopian tube patency tests; intravasation of contrast media; quality control; risk factors; ultrasonography

Year:  2018        PMID: 30597629     DOI: 10.1002/jum.14914

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  4 in total

1.  Operator's Influence on Contrast Agent Intravasation During Hysterosalpingo-Contrast Sonography: Explanation Based on a Physics Model.

Authors:  Bin-Bin Jin; Yan Ma; Xiu-Hua Zhao; Yi-Ling Teng; Shang-Yong Zhu
Journal:  Int J Gen Med       Date:  2022-10-07

2.  Development of a Nomogram for Predicting Intravasation Before Transvaginal 4-Dimensional Hysterosalpingo-Contrast Sonography.

Authors:  Yi Jin; Wendi Huang; Qinhong Qv; Shuling Liu
Journal:  Int J Womens Health       Date:  2022-04-21

3.  Green urine sign after laparoscopic chromopertubation as an effect of severe contrast intravasation: a report of three cases.

Authors:  Piotr Szkodziak; Andrzej Woźniak; Filip Szkodziak; Grzegorz Buszewicz; Piotr Czuczwar; Sławomir Woźniak
Journal:  J Int Med Res       Date:  2020-08       Impact factor: 1.671

4.  Spontaneous conception outcome in infertile women after four-dimensional hysterosalpingo-contrast-sonography.

Authors:  Yu Liu; Ning Zhang; Yanni He; Jiayao Shi; Meijun Zhou; Jingjiao Xu; Hongmei Liu
Journal:  BMC Pregnancy Childbirth       Date:  2020-10-20       Impact factor: 3.007

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.