Literature DB >> 30597459

Robust motion correction for cardiac T1 and ECV mapping using a T1 relaxation model approach.

Sofie Tilborghs1, Tom Dresselaers2, Piet Claus3, Guido Claessen4, Jan Bogaert2, Frederik Maes5, Paul Suetens5.   

Abstract

T1 and ECV mapping are quantitative methods for myocardial tissue characterization using cardiac MRI, and are highly relevant for the diagnosis of diffuse myocardial diseases. Since the maps are calculated pixel-by-pixel from a set of MRI images with different T1-weighting, it is critical to assure exact spatial correspondence between these images. However, in practice, different sources of motion e.g. cardiac motion, respiratory motion or patient motion, hamper accurate T1 and ECV calculation such that retrospective motion correction is required. We propose a new robust non-rigid registration framework combining a data-driven initialization with a model-based registration approach, which uses a model for T1 relaxation to avoid direct registration of images with highly varying contrast. The registration between native T1 and enhanced T1 to obtain a motion free ECV map is also calculated using information from T1 model-fitting. The method was validated on three datasets recorded with two substantially different acquisition protocols (MOLLI (dataset 1 (n=15) and dataset 2 (n=29)) and STONE (dataset 3 (n = 210))), one in breath-hold condition and one free-breathing. The average Dice coefficient increased from 72.6 ± 12.1% to 82.3 ± 7.4% (P < 0.05) and mean boundary error decreased from 2.91 ± 1.51mm to 1.62 ± 0.80mm (P < 0.05) for motion correction in a single T1-weighted image sequence (3 datasets) while average Dice coefficient increased from 63.4 ± 22.5% to 79.2 ± 8.5% (P < 0.05) and mean boundary error decreased from 3.26 ± 2.64mm to 1.77 ± 0.86mm (P < 0.05) between native and enhanced sequences (dataset 1 and 2). Overall, the native T1 SD error decreased from 67.32 ± 32.57ms to 58.11 ± 21.59ms (P < 0.05), enhanced SD error from 30.15 ± 25ms to 22.74 ± 8.94ms (P < 0.05) and ECV SD error from 10.08 ± 9.59% to 5.42 ± 3.21% (P < 0.05) (dataset 1 and 2).
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Cardiac ECV mapping; Cardiac T1 mapping; Image registration; Motion correction

Year:  2018        PMID: 30597459     DOI: 10.1016/j.media.2018.12.004

Source DB:  PubMed          Journal:  Med Image Anal        ISSN: 1361-8415            Impact factor:   8.545


  5 in total

1.  Case Report: Treatment of Hypertrophic Cardiomyopathy With Stereotactic Body Radiotherapy.

Authors:  Longzihui Xiao; Jiayi Liu; Yingzhe Zhang; Yuefei Liu; Yan Tang; Minping Zhang; Zhuyuan Ding; Enhua Xiao; Taili Chen
Journal:  Front Med (Lausanne)       Date:  2022-06-01

2.  Native T1 mapping and extracellular volume fraction for differentiation of myocardial diseases from normal CMR controls in routine clinical practice.

Authors:  Rawiwan Thongsongsang; Thammarak Songsangjinda; Prajak Tanapibunpon; Rungroj Krittayaphong
Journal:  BMC Cardiovasc Disord       Date:  2021-06-03       Impact factor: 2.298

3.  Improved fetal blood oxygenation and placental estimated measurements of diffusion-weighted MRI using data-driven Bayesian modeling.

Authors:  Dimitra Flouri; David Owen; Rosalind Aughwane; Nada Mufti; Kasia Maksym; Magdalena Sokolska; Giles Kendall; Alan Bainbridge; David Atkinson; Tom Vercauteren; Sebastien Ourselin; Anna L David; Andrew Melbourne
Journal:  Magn Reson Med       Date:  2019-11-19       Impact factor: 4.668

4.  Endurance exercise and the risk of cardiovascular pathology in men: a comparison between lifelong and late-onset endurance training and a non-athletic lifestyle - rationale and design of the Master@Heart study, a prospective cohort trial.

Authors:  Ruben De Bosscher; Christophe Dausin; Piet Claus; Jan Bogaert; Steven Dymarkowski; Kaatje Goetschalckx; Olivier Ghekiere; Ann Belmans; Caroline M Van De Heyning; Paul Van Herck; Bernard Paelinck; Haroun El Addouli; André La Gerche; Lieven Herbots; Hein Heidbuchel; Rik Willems; Guido Claessen
Journal:  BMJ Open Sport Exerc Med       Date:  2021-04-16

5.  Motion correction of free-breathing magnetic resonance renography using model-driven registration.

Authors:  Dimitra Flouri; Daniel Lesnic; Constantina Chrysochou; Jehill Parikh; Peter Thelwall; Neil Sheerin; Philip A Kalra; David L Buckley; Steven P Sourbron
Journal:  MAGMA       Date:  2021-06-23       Impact factor: 2.310

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.