OBJECTIVE: This study aims to evaluate the occlusal characteristics of full edentulous patients with implant-supported prostheses and to provide a reference with the occlusal situation for clinicians.
METHODS: A Teetester occlusal analysis system was used with 30 full edentulous patients of implant-supported fixed denture (test group) in comparison with 30 natural dentition (control group). The percentage of occlusal force distribution were measured, as well as the occlusal time at the intercuspal, protrusion, and left and right lateral positions.
RESULTS: Compared with control group, the occlusion time, maximum occlusal force in intercuspal of test group significantly reduced (P<0.05); while control group was obviously superior to test group in the left and right bit force degree. Disclusion time in protrusion, occlusion times in lateral positions of test group also significantly reduced (P<0.05). There were no significant differences in average occlusion force, percentage of total force in anterior teeth, and lateral occlusion between test group and control group.
CONCLUSIONS: The maximum occlusal force in intercuspal of full edentulous patients with implant-supported prostheses reduce. The occlusal force in protrusive occlusion is concentrated in the front teeth, and the group function occlusion is the main lateral occlusal pattern.

Entities:  

Keywords:  edentulous patient; fixed denture; implanting; occlusal analysis system; overdenture

Mesh:

Year:  2018        PMID: 30593108      PMCID: PMC7039791          DOI: 10.7518/hxkq.2018.06.009

Source DB:  PubMed          Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi        ISSN: 1000-1182


  1 in total

1.  [Gnathology in implant-supported fixed restoration in edentulous mandible].

Authors:  Wen-Qian Yu; Xiao-Qian Li; Li Ma; Xiao-Ni Ma; Xin Xu
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2020-02-01
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.