Effects of time and clear aligner removal frequency on the force delivered by different polyethylene terephthalate glycol-modified materials determined with thin-film pressure sensors.

Adham Skaik1, Xiao Li Wei2, Islam Abusamak1, Iddi Iddi1.   

Abstract

INTRODUCTION: Many factors influence the force changes of clear aligners. The purpose of this study was to identify the various factors that influence the force changes generated by polyethylene terephthalate glycol-modified (PET-G) materials. Therefore, a force measurement system based on a flexible thin-film pressure sensor was established.
METHODS: A series of clear aligners with 2 material properties and different activations at the maxillary central incisor, maxillary second premolar, and maxillary permanent first molar was designed and fabricated. The first material was conventional PET-G; the second material was modified PET-G with a higher modulus of elasticity and greater abrasion resistance. Several models, including teeth and aligners, were produced. Then, a force change detection device, including a thin-film pressure sensor, a signal acquisition circuit board, and a computer, was applied to measure changes in the forces delivered by the conventional and modified PET-G materials with increased frequencies of appliance removal. Finally, the forces were repeatedly measured to detect the force changes over 48 hours.
RESULTS: The forces of both materials decreased similarly over time. These forces also decreased when the aligner removal frequency increased, but the forces decreased differently. The modified PET-G, with a higher modulus of elasticity and greater abrasion resistance, showed a more stable and lower force change than did the conventional PET-G.
CONCLUSIONS: The forces delivered by both materials were within the orthodontic force range. Force changes were apparent when the appliance removal frequency increased. Compared with the conventional material, the modified PET-G material showed better stability. Therefore, the modified PET-G is a promising and applicable material with advantages for both orthodontists and patients.
Copyright © 2018 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 30591174     DOI: 10.1016/j.ajodo.2018.03.017

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  7 in total

1.  Force decay of polyethylene terephthalate glycol aligner materials during simulation of typical clinical loading/unloading scenarios.

Authors:  Fayez Elkholy; Silva Schmidt; Falko Schmidt; Masoud Amirkhani; Bernd G Lapatki
Journal:  J Orofac Orthop       Date:  2021-12-09       Impact factor: 1.938

2.  Comparative mechanical testing for different orthodontic aligner materials over time - in vitro study.

Authors:  Clara-Marie Nowak; Ahmed Othman; Dragan-Alexander Ströbele; Constantin von See
Journal:  J Clin Exp Dent       Date:  2022-06-01

3.  Three-dimensional analysis of aligner gaps and thickness distributions, using hard x-ray tomography with micrometer resolution.

Authors:  Rémi Ammann; Christine Tanner; Georg Schulz; Bekim Osmani; Prasad Nalabothu; Tino Töpper; Bert Müller
Journal:  J Med Imaging (Bellingham)       Date:  2022-06-16

4.  Flexible Wearable Pressure Sensor Based on Collagen Fiber Material.

Authors:  Zhiqing Peng; Shijie Zheng; Xia Zhang; Junlong Yang; Shizhou Wu; Chen Ding; Lei Lei; Lei Chen; Guoying Feng
Journal:  Micromachines (Basel)       Date:  2022-04-28       Impact factor: 3.523

5.  The force effects of two types of polyethylene terephthalate glyc-olmodified clear aligners immersed in artificial saliva.

Authors:  Biao Xiang; Xingxing Wang; Gang Wu; Yichen Xu; Menghan Wang; Yanjing Yang; Qingyu Wang
Journal:  Sci Rep       Date:  2021-05-12       Impact factor: 4.379

6.  Pressure Differences from Clear Aligner Movements Assessed by Pressure Sensors.

Authors:  Ho-Jung Son; Kyeong-Ho Lee; Ji-Young Sim; Hae-Young Kim; Ji-Hwan Kim; Woong-Chul Kim
Journal:  Biomed Res Int       Date:  2020-03-12       Impact factor: 3.411

7.  Risk Factors of Composite Attachment Loss in Orthodontic Patients during Orthodontic Clear Aligner Therapy: A Prospective Study.

Authors:  Chen Yaosen; A M Mohamed; Wang Jinbo; Zheng Ziwei; Maher Al-Balaa; Yang Yan
Journal:  Biomed Res Int       Date:  2021-01-23       Impact factor: 3.411

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.