Literature DB >> 30583283

Hexaammineruthenium (II)/(III) as alternative redox-probe to Hexacyanoferrat (II)/(III) for stable impedimetric biosensing with gold electrodes.

Julian D Schrattenecker1, Rudolf Heer2, Eva Melnik2, Thomas Maier2, Günter Fafilek3, Rainer Hainberger2.   

Abstract

Gold electrodes have been used in a wide range of electrochemical biosensors because their functionalization process with thiols has been well described and, in general, they offer good chemical stability. However, one of the most commonly used redox-pairs in electrochemical impedance spectroscopy, Hexacyanoferrate (II)/(III), causes corrosion of the gold electrodes and consequently damages the surface modification. This leads to alterations of the sensing signals, and thus, renders the quantitative and sensitive detection of target molecules virtually impossible. To overcome this problem we introduced the in-situ generation of Hexaammineruthenium (II)/(III) as redox-pair during the impedimetric measurement by applying a DC-bias. This DC-bias was chosen in such a way that it supplied Hexaammineruthenium (II) in a suitable concentration at the electrode surface by reducing Hexaammineruthenium (III). We compared the stability of photolithographically fabricated thin-film and screen-printed gold electrodes in Hexacyanoferrate and Hexaammineruthenium solutions. Further, long-time characterization of the electrochemical properties with cyclic voltammetry and electrochemical impedance spectroscopy revealed that Hexaammineruthenium (II)/(III) was an excellent redox-pair for stable impedimetric measurements with gold electrodes. To demonstrate the suitability of Hexaammineruthenium for biosensing we applied it for the impedimetric detection of human-IgG. This biosensor exhibited a linear range from 11.3 ng/mL to 113 μg/mL, which is a suitable range for diagnostic applications.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Electrochemical biosensor; Electrochemical impedance spectroscopy; Gold electrode, Hexacyanoferrat (II)/(III); Hexaammineruthenium (II)/(III); IgG

Mesh:

Substances:

Year:  2018        PMID: 30583283     DOI: 10.1016/j.bios.2018.12.007

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  8 in total

Review 1.  Electrochemical biosensors for pathogen detection.

Authors:  Ellen Cesewski; Blake N Johnson
Journal:  Biosens Bioelectron       Date:  2020-04-12       Impact factor: 10.618

2.  Application of silver solid amalgam electrodes in electrochemical detection of DNA damage.

Authors:  Veronika Svitková; Katarína Nemčeková; Vlastimil Vyskočil
Journal:  Anal Bioanal Chem       Date:  2022-02-07       Impact factor: 4.142

Review 3.  Advances in Electrochemical Impedance Spectroscopy Detection of Endocrine Disruptors.

Authors:  Lucian-Gabriel Zamfir; Mihaela Puiu; Camelia Bala
Journal:  Sensors (Basel)       Date:  2020-11-11       Impact factor: 3.576

4.  Toward a Practical Impedimetric Biosensor: A Micro-Gap Parallel Plate Electrode Structure That Suppresses Unexpected Device-to-Device Variations.

Authors:  Haruka Honda; Yusuke Kusaka; Haiyun Wu; Hideaki Endo; Daiju Tsuya; Hitoshi Ohnuki
Journal:  ACS Omega       Date:  2022-03-23

Review 5.  Electrochemical Impedance Spectroscopy in the Characterisation and Application of Modified Electrodes for Electrochemical Sensors and Biosensors.

Authors:  Christopher M A Brett
Journal:  Molecules       Date:  2022-02-23       Impact factor: 4.411

6.  Electrochemical Sensor Based on Iron(II) Phthalocyanine and Gold Nanoparticles for Nitrite Detection in Meat Products.

Authors:  Svetlana I Dorovskikh; Darya D Klyamer; Anastasiya D Fedorenko; Natalia B Morozova; Tamara V Basova
Journal:  Sensors (Basel)       Date:  2022-08-02       Impact factor: 3.847

Review 7.  Affinity Assays for Cannabinoids Detection: Are They Amenable to On-Site Screening?

Authors:  Mihaela Puiu; Camelia Bala
Journal:  Biosensors (Basel)       Date:  2022-08-06

8.  Boron doped diamond thin films for the electrochemical detection of SARS-CoV-2 S1 protein.

Authors:  Suzanne Witt; Alexis Rogien; Diana Werner; James Siegenthaler; Raymond Lesiyon; Noelle Kurien; Robert Rechenberg; Nina Baule; Aaron Hardy; Michael Becker
Journal:  Diam Relat Mater       Date:  2021-07-28       Impact factor: 3.315

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.