BACKGROUND: Chronic obstructive pulmonary disease (COPD) that includes multiple mechanisms such as inflammation, infection, smoking, hypoxia, and lack of antioxidant response can cause oxidative stress. In our study, we aimed to determine the changes in some oxidative stress [malondialdehyde and glutathione] and some cellular immunity markers (neopterin and TGF-b) in patients diagnosed with COPD and determine the damage to the organism.Entities:
Keywords: cellular immunity; chronic obstructive pulmonary disease; oxidative stress
Year: 2018 PMID: 30581341 PMCID: PMC6294106 DOI: 10.1515/jomb-2017-0035
Source DB: PubMed Journal: J Med Biochem ISSN: 1452-8266 Impact factor: 3.402
Figure 1Oxidative stress markers (MDA and GSH) of patients with COPD and control group.
The working conditions and system parameters of the HPLC system used in the MDA, GSH and neopterin studies.
| Working condition | System Parameters | ||
|---|---|---|---|
| MDA | GSH | Neopterin | |
| HPLC Model | Agilent Technologies 1200 Series | ||
| Sensor | Flouresans Sensor | ||
| Mobile Phase | - | - | 6.4 pH 0.015 mol/L phosphate buffer |
| Column material | Bischoff Prontosil Eurobond, 5 μm; 125 mm × 4 mm | MZ Inertsil ODS, 5 μm; 125 mm × 4 mm | Analytical Column 4.6 × 250 mm, Allsphere ODS- 2, C18 5 μm reverse-phase Protector Column Spherisorb ODS-2, C18 5 mm reverse-phase |
| Wavelength | 515 nm excitation and 553 nm emission | 385 nm excitation and 515 nm emission | 353 nm excitation and 438 nm emission |
| Flow Rate | 0.8 to 1.0 mL/minute | 0.75 to 1.0 mL/minute | 0.8 mL/minute |
| Sample Volume | 20 μL | ||
| Operation time | 4 minute | 20 minute | |
| Temperature | 30 °C | ||
| Discrimination | - | - | |
Skewness and kurtosis values of all parameters.
| Skewness | Skewness STD Error | R | Kurtosis | Kurtosis STD Error | R | |
|---|---|---|---|---|---|---|
| MDA | 0.753 | 0.23 | 0.523 | -0.251 | 0.457 | -0.708 |
| GSH | 0.379 | 0.23 | 0.149 | -0.439 | 0.457 | -0.896 |
| NP | -0.956 | 0.23 | -1.186 | -0.944 | 0.457 | -1.401 |
| TGFB | -0.972 | 0.23 | -1.202 | -0.876 | 0.457 | -1.333 |
Skewness - Skewness STD Error
Kurtosis - Kurtosis STD Error, R2 ‹ ǀ Kurtosis ǀ = normal distribution
Demographic data of groups, both healthy-control and patients with COPD.
| Control (n=30) | COPD (n=80) | |
|---|---|---|
| Gender (Male/Female) Age range | 17/13 | 35–65 |
| 48/32 | 45–73 |
Values of oxidative stress markers (MDA and GSH) and immune markers (NP and TGF-b) of patients with COPD and control group and their 95% confidence intervals.
| Parameters | Groups | n | 95 % CI | |
|---|---|---|---|---|
| Min-Max | ||||
| MDA, μmmol/L* | Control | 30 | 1.38 ± 0.16 | 1.31–1.44 |
| COPD | 80 | 1.93 ± 0.48 | 1.82–2.03 | |
| GSH, μmol/L* | Control | 30 | 394.77 ± 30.65 | 383.32–406.21 |
| COPD | 80 | 275.21 ± 41.19 | 266.04–284.37 | |
| NP, μmmol/L* | Control | 30 | 16.28 ± 1.06 | 15.88–16.68 |
| COPD | 80 | 38.15 ± 1.86 | 37.73–38.56 | |
| TGF-beta, pg/mL* | Control | 30 | 4.28 ± 0.40 | 4.13–4.43 |
| COPD | 80 | 8.74 ± 0.41 | 8.64–8.83 |
MDA: Malondialdehyde, GSH: Glutathione, NP: Neopterin; TGF-beta: Transforming growth factor-beta; CI: Confidence interval for mean;
Each of groups is mean value and standard deviation.*p<0.005; statistically significant differences were found between the groups.