Literature DB >> 30577734

Trigonometry in daily ultrasound practice.

Alessandro De Cassai1, Ludovica Sandei2, Michele Carron2.   

Abstract

Entities:  

Mesh:

Year:  2018        PMID: 30577734      PMCID: PMC6303877          DOI: 10.1186/s13054-018-2282-8

Source DB:  PubMed          Journal:  Crit Care        ISSN: 1364-8535            Impact factor:   9.097


× No keyword cloud information.
We have read with interest the editorial by Piton et al. [1] regarding application of Pythagoras’ theorem in central venous cannulation. Geometry is at the base of our daily life and we should apply his theorems and axioms to obtain the best result in our daily practice. We believe that trigonometry is another important branch of geometry in addition to Pythagoras’ theorem that has to be taken into consideration while performing invasive procedures under ultrasound guidance. Sine, cosine and tangent are the basis of trigonometry, they represent the ratio between the sides of a right-angled triangle. Sin(α) is the ratio between side B and the hypotenuse (H) (Fig. 1), Cos(α) is the ratio between side A and the hypotenuse (H), and Tan(α) is the ratio between side B and side A. It is important to note that, for a given angle α, the ratio between the sides is unconnected from the triangle size.
Fig. 1

Internal jugular vein ultrasound anatomy. H hypotenuse; A and B are catheti of the triangle

Internal jugular vein ultrasound anatomy. H hypotenuse; A and B are catheti of the triangle As already stated by Piton [1], in our ultrasound daily practice, we constantly build right-angled triangles: the hypotenuse is the needle route, side A is the distance measured on the skin between needle insertion point and target projection on the skin, and side B is the depth of the target. Side B is determined by the patient’s anatomy and the operator cannot modify it. As reported by Schulman et al. [2], needle/skin angulation between 30° and 45° is considered to be ideal while performing ultrasound procedure. Trigonometry is helpful in determining which targets can be reached with such needle angulation. At 45° angulation tan(α) is equal to 1, meaning that side A and side B have to be equal. For example, if our target jugular internal vein is 2 cm deep, the needle has to be inserted 2 cm from the target. Generalizing, we have a good needle visualization whenever Tan(α) ≤ 1 with side B equal to or shorter than side A. In conclusion, physicians have to take into account target depth while choosing the ultrasound linear probe of appropriate size to be able to visualize all needle routes and the needle skin entrance site.
  2 in total

1.  Ultrasound-Guided Cannulation of the Subclavian Vein.

Authors:  Peter M Schulman; Neal S Gerstein; Matthias J Merkel; Dana A Braner; Ken Tegtmeyer
Journal:  N Engl J Med       Date:  2018-07-05       Impact factor: 91.245

2.  Ultrasound-guided vessel puncture: calling for Pythagoras' help.

Authors:  Gaël Piton; Gilles Capellier; Hadrien Winiszewski
Journal:  Crit Care       Date:  2018-11-08       Impact factor: 9.097

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.