Literature DB >> 30573350

MRI detection of radiographically occult fractures of the hip and pelvis in the elderly: Comparison of T2-weighted Dixon sequence with T1-weighted and STIR sequences.

B Heynen1, C Tamigneaux1, V Pasoglou1, J Malghem1, B Vande Berg1, T Kirchgesner2.   

Abstract

PURPOSE: To compare the diagnostic performance of T2-weighted Dixon, T1-weighted and Short-Tau Inversion Recovery (STIR) MR images for the detection of radiographically occult fractures (ROF) of the hip and pelvis in elderly patients after low-energy trauma.
MATERIALS AND METHODS: A total of 22 patients older than 50 years with suspected ROF after low-energy trauma was prospectively included. There were 9 men and 13 women, with a mean age of 80.9 years±12.5 (SD) (range: 52-100 years). T2-weighted Dixon, T1-weighted and STIR MR images were analyzed by 3 independent radiologists blinded to the clinical data and the results of other imaging examinations. Readers separately assessed each series of images for the presence of fractures on a per bone analysis. Diagnostic performance of each reader was compared for Dixon and non-Dixon sequences using contingency tables and McNemar test. Interobserver agreement was evaluated according to the Fleiss-Cuzick's kappa statistics.
RESULTS: The sensitivity of the Dixon sequence in the detection of ROF ranged from 90.9% (20/22; 95% CI: 70.8-98.9%) to 100% (22/22; 95% CI: 84.6-100%). The sensitivities of the non-Dixon sequences in the detection of ROF ranged from 95.5% (21/22; 95% CI: 77.2-99.9%) to 100% (22/22; 95% CI: 84.6-100%). For each reader, there were no statistical differences between combined Dixon and combined non-Dixon images for the detection of ROF (P=0.12, 0.99 and 0.99). Interobserver agreement with T2-weighted Dixon water-only images was significantly lower than that with the STIR sequence (0.70-0.79 vs. 0.87-0.93).
CONCLUSION: T2-weighted Dixon may be a second-rate alternative to T1-weighted and STIR sequences for the detection of ROF of the hip and pelvis in elderly patients.
Copyright © 2018 Société française de radiologie. Published by Elsevier Masson SAS. All rights reserved.

Entities:  

Keywords:  Bone fracture; Dixon sequence; Hip; MRI; Pelvis

Mesh:

Year:  2018        PMID: 30573350     DOI: 10.1016/j.diii.2018.11.008

Source DB:  PubMed          Journal:  Diagn Interv Imaging        ISSN: 2211-5684            Impact factor:   4.026


  1 in total

1.  Magnetic Resonance Imaging has Better Accuracy in Detecting New-Onset Rib Fractures as Compared to Computed Tomography.

Authors:  Tao Zhang; Jing Wu; Yu-Chen Chen; Xinying Wu; Lingquan Lu; Cunnan Mao
Journal:  Med Sci Monit       Date:  2021-01-11
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.