Literature DB >> 305732

[Permeability of hydrogel plastics (PHEMA) to different substances of corneal metabolism (author's transl)].

U Mester, H J Stein, J Meier.   

Abstract

With a new two-chamber apparatus for diffusion measurements, the permeability of Poly (2-hydroxy-ethyl-methacrylate) (PHEMA) is determined for metabolites of the corneal metabolism. Except for ATP, all substances tested, including several amino acids, penetrated the PHEMA material. Compared to the corneal stroma, the permeability of PHEMA is relatively low. Therefore, intracorneal implants of this hydrogel should be as thin as possible.

Entities:  

Mesh:

Substances:

Year:  1978        PMID: 305732     DOI: 10.1007/bf00414398

Source DB:  PubMed          Journal:  Albrecht Von Graefes Arch Klin Exp Ophthalmol        ISSN: 0065-6100


  11 in total

1.  Effect of intralamellar plastic membranes on corneal physiology.

Authors:  W F KNOWLES
Journal:  Am J Ophthalmol       Date:  1961-05       Impact factor: 5.258

Review 2.  [Why is the cornea transparent?].

Authors:  M Reim
Journal:  Ber Zusammenkunft Dtsch Ophthalmol Ges       Date:  1972

3.  Diffusion properties of hydrophilic materials.

Authors:  T F Gumpelmayer; G W Schwach
Journal:  Am J Optom Arch Am Acad Optom       Date:  1973-11

4.  [Trial with 2-hydroxy-ethyl-methacrylate lenses as keratophakia material].

Authors:  U Mester; K Roth; U Dardenne
Journal:  Ber Zusammenkunft Dtsch Ophthalmol Ges       Date:  1974

5.  Solute permeability of the corneal endothelium and Descemet's membrane.

Authors:  J H Kim; K Green; M Martinez; D Paton
Journal:  Exp Eye Res       Date:  1971-11       Impact factor: 3.467

6.  [Nutrition of the cornea having a water impermeable membrane as artificial endothelium].

Authors:  M Reim; J Friend; C H Dohlman
Journal:  Ber Zusammenkunft Dtsch Ophthalmol Ges       Date:  1969

7.  Permeability of hydrophilic contact lenses.

Authors:  D R Morrison; H F Edelhauser
Journal:  Invest Ophthalmol       Date:  1972-01

8.  Synthetic polymers in corneal surgery. I. Glyceryl methacrylate.

Authors:  C H Dohlman; M F Refojo; J Rose
Journal:  Arch Ophthalmol       Date:  1967-02

9.  [Corneal changes after implantation of intralamellar teflon-membranes (author's transl)].

Authors:  H Schmitt
Journal:  Klin Monbl Augenheilkd       Date:  1976-04       Impact factor: 0.700

10.  Incorporation of sulfate-35S, N-acetylglucosamine-1-14C, glucose-1-14C, and galactose-1-14C into calf and beef corneal glycosaminoglycans.

Authors:  C H Dohlman; B Wortman; S Hultman
Journal:  Invest Ophthalmol       Date:  1965-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.