Literature DB >> 30573119

Less Pulmonary Vein Reconnection at Redo Procedures Following Radiofrequency Point-by-Point Antral Pulmonary Vein Isolation With the Use of Contemporary Catheter Ablation Technologies.

Gabor Sandorfi1, Moises Rodriguez-Mañero2, Johan Saenen1, Aurora Baluja3, Wim Bories1, Wim Huybrechts1, Hielko Miljoen1, Lien Vandaele1, Hein Heidbuchel1, Andrea Sarkozy4.   

Abstract

OBJECTIVES: This study investigated whether real-world use of contemporary technologies changed pulmonary vein (PV) reconnection and redo pulmonary vein isolation (PVI) procedure frequencies.
BACKGROUND: Previous studies consistently reported that following PVI recurrence of PV conduction is observed in >80% of patients.
METHODS: Consecutive patients undergoing 529 first and/or redo radiofrequency point-by-point PVI between January 2013 and December 2016 were included.
RESULTS: Between 2013 and 2016, redo PVI rate in atrial fibrillation significantly decreased (p < 0.001); in ≤12 months, first redo PVI rate decreased from 19% to 4%. The percentage of patients having PV reconnection at second PVI significantly decreased from 90% to 29% (p = 0.001). One PVI was performed in 393 and >1 in 79 patients. Female sex was associated with >1 PVI (hazard ratio [HR]: 1.86; 95% confidence interval [CI]: 1.10 to 3.13; p = 0.02). Sixty patients underwent first and second PVI in the study period. Female sex (HR: 2.79; 95% CI: 1.67 to 4.64; p < 0.001) and left atrial diameter (HR: 1.05; 95% CI: 1.01 to 1.08; p = 0.01) were associated with more and use of automatic ablation annotation algorithm during first PVI with fewer (HR: 0.54; 95% CI: 0.32 to 0.92; p = 0.02) redo PVI procedures. In 31 of 60 patients, ≥1 PV was reconnected at second PVI. The need for "touch-up" applications at the first PVI was the only predictor of PV reconnection.
CONCLUSIONS: Redo rate in atrial fibrillation and PV reconnection at redo PVI significantly decreased in recent years. Male sex, left atrial diameter, and use of automatic ablation annotation algorithm at first PVI were associated with fewer redo procedures. First-pass isolation was associated with lower PV reconnection rate at second procedure. Female sex was associated with more redo procedures but not higher PV reconnection frequencies.
Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  atrial fibrillation; catheter ablation; contact force; pulmonary vein isolation; reconnection

Mesh:

Year:  2018        PMID: 30573119     DOI: 10.1016/j.jacep.2018.09.020

Source DB:  PubMed          Journal:  JACC Clin Electrophysiol        ISSN: 2405-500X


  6 in total

1.  The feasibility and effectiveness of a streamlined single-catheter approach for radiofrequency atrial fibrillation ablation.

Authors:  Shui Hao Chin; Jim O'Brien; Gianluca Epicoco; Prithvi Peddinti; Akanksha Gupta; Simon Modi; Johan Waktare; Richard Snowdon; Dhiraj Gupta
Journal:  J Arrhythm       Date:  2020-06-26

2.  Differences between gap-related persistent conduction and carina-related persistent conduction during radiofrequency pulmonary vein isolation.

Authors:  Mark J Mulder; Michiel J B Kemme; Marco J W Götte; Peter M van de Ven; Herbert A Hauer; Giovanni J M Tahapary; Albert C van Rossum; Cornelis P Allaart
Journal:  J Cardiovasc Electrophysiol       Date:  2020-05-22

3.  Impact of Left Atrial Bipolar Electrogram Voltage on First Pass Pulmonary Vein Isolation During Radiofrequency Catheter Ablation.

Authors:  Lohit Garg; Naga Venkata K Pothineni; J Michael Daw; Matthew C Hyman; Jeffrey Arkles; Cory M Tschabrunn; Pasquale Santangeli; Francis E Marchlinski
Journal:  Front Physiol       Date:  2020-12-15       Impact factor: 4.566

4.  Cavotricuspid isthmus ablation guided by force-time integral - A randomized study.

Authors:  Dimitrios Asvestas; Vasileios Sousonis; George Kotsovolis; Stavros Karanikas; Anastasia Xintarakou; Eleftherios Sakadakis; Angelos G Rigopoulos; Andreas S Kalogeropoulos; Panos Vardas; Stylianos Tzeis
Journal:  Clin Cardiol       Date:  2022-03-17       Impact factor: 3.287

5.  Impact of High-Power and Very High-Power Short-Duration Radiofrequency Ablation on Procedure Characteristics and First-Pass Isolation During Pulmonary Vein Isolation.

Authors:  Zoltán Salló; Péter Perge; Bernadett Balogi; Gábor Orbán; Katalin Piros; Szilvia Herczeg; Klaudia Vivien Nagy; István Osztheimer; Pál Ábrahám; Béla Merkely; László Gellér; Nándor Szegedi
Journal:  Front Cardiovasc Med       Date:  2022-07-07

6.  Novel Clue to Locate Conduction Gaps in the Pulmonary Vein Isolation Ablation Line.

Authors:  Hai-Yang Xie; Xiao-Gang Guo; Jian-du Yang; Yan-Qiao Chen; Zhong-Jing Cao; Qi Sun; Jian Ma
Journal:  Front Cardiovasc Med       Date:  2021-07-12
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.