Essential considerations for accurate evaluation of photoneutron contamination in Radiotherapy.

Amir Hossein Karimi1, Hrvoje Brkić2, Daryoush Shahbazi-Gahrouei3, Somayeh Biparva Haghighi4, Iraj Jabbari5.   

Abstract

Nowadays, high-energy X-rays produced by medical linear accelerators (LINACs) are widely used in many Radiation Therapy (RT) centers. High-energy photons (> 8 MeV) produce undesired neutrons in the LINAC head which raise concerns about unwanted neutron dose to the patients and RT personnel. Regarding the significance of radiation protection in RT, it is important to evaluate photoneutron contamination inside the RT room. Unfortunately, neutron dosimeters used for this purpose have limitations that can under the best conditions cause to > 10% uncertainty. In addition to this uncertainty, the present Monte Carlo (MC) study introduces another uncertainty in measurements (nearly up to 20%) when neutron ambient dose equivalent (Hn*(10)) is measured at the patient table or inside the maze and the change in neutron energy is ignored. This type of uncertainty can even reach 35% if Hn*(10) is measured by dosimeters covered by a layer of 10B as converter. So, in these cases, neglecting the change in neutron energy can threaten the credibility of measured data and one should attend to this energy change in order to reduce measurement uncertainty to the possible minimum. This study also discusses the change in neutron spectra and Hn*(10) at the patient table caused by removing a typical RT room from MC simulations. Under such conditions, neutron mean energy (Ēn) overestimated by 0.2-0.4 MeV at the patient table. Neutron fluence (φn) at the isocenter (IC) was underestimated by 23-54% for different field sizes that caused Hn*(10) to be miscalculated up to 24%. This finding informs researchers that for accurate evaluation of Hn*(10) at the patient table, simulating the RT room is an effective parameter in MC studies.
Copyright © 2018 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  LINAC; Medical dosimetry; Monte Carlo; Photoneutron contamination; Radiotherapy

Mesh:

Year:  2018        PMID: 30572262     DOI: 10.1016/j.apradiso.2018.12.007

Source DB:  PubMed          Journal:  Appl Radiat Isot        ISSN: 0969-8043            Impact factor:   1.513


  2 in total

1.  Semi-experimental assessment of neutron equivalent dose and secondary cancer risk for off-field organs in glioma patients undergoing 18-MV radiotherapy.

Authors:  Soheil Elmtalab; Iraj Abedi; Zahra Alirezaei; Mohammad Hossein Choopan Dastjerdi; Ghazale Geraily; Amir Hossein Karimi
Journal:  PLoS One       Date:  2022-07-29       Impact factor: 3.752

2.  The influence of shielding reinforcement in a vault with limited dimensions on the neutron dose equivalent in vicinity of medical electron linear accelerator.

Authors:  Ana Ivkovic; Dario Faj; Mladen Kasabasic; Marina Poje Sovilj; Ivana Krpan; Marina Grabar Branilovic; Hrvoje Brkic
Journal:  Radiol Oncol       Date:  2020-05-02       Impact factor: 2.991

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.