Literature DB >> 30569808

Air Embolism During TEVAR: Liquid Perfluorocarbon Absorbs Carbon Dioxide in a Combined Flushing Technique and Decreases the Amount of Gas Released From Thoracic Stent-Grafts During Deployment in an Experimental Setting.

Fiona Rohlffs1, Constantin Trepte2, Krassi Ivancev1, Nikolaos Tsilimparis1, Vladimir Makaloski1, E Sebastian Debus1, Tilo Kölbel1.   

Abstract

PURPOSE: To investigate the influence of flushing thoracic stent-grafts with carbon dioxide and perfluorocarbon on the amount of gas released during stent-graft deployment in thoracic endovascular aortic repair (TEVAR).
MATERIALS AND METHODS: Ten TX2 ProForm thoracic stent-grafts were deployed into a water-filled container with a curved plastic pipe and flushed sequentially with carbon dioxide, 20 mL of liquid perfluorocarbon (PFC), and 60 mL of saline. Released gas was measured using a calibrated setup. The volume of released gas was compared with the results of an earlier published reference group, in which identical stent-grafts were flushed with 60 mL saline alone as recommended in the instructions for use.
RESULTS: The average amount of gas released in the test group was 0.076 mL, significantly lower (p<0.001) than the mean 0.79 mL of gas released in the reference group. Big bubbles appearing at the tip of the sheath when deployment was started were seen in all grafts of the reference group but in only 2 of the test group stent-grafts. Small bubbles were less frequent in the test group.
CONCLUSION: The amount of gas released from thoracic stent-grafts during deployment can be influenced by different flushing techniques. The use of PFC in addition to the carbon dioxide flushing technique reduces the volume of gas released during deployment of tubular thoracic stent-grafts to a few microliters. This significant effect is presumably based on the high solubility of carbon dioxide in perfluorocarbon and could be a potential future approach to lower the risk of cerebral injury and stroke from air embolism during TEVAR.

Entities:  

Keywords:  air embolism; aorta; aortic aneurysm; carbon dioxide; endograft; flushing technique; perfluorocarbon; stent-graft; stroke; thoracic aorta; thoracic endovascular aortic repair

Mesh:

Substances:

Year:  2018        PMID: 30569808     DOI: 10.1177/1526602818819501

Source DB:  PubMed          Journal:  J Endovasc Ther        ISSN: 1526-6028            Impact factor:   3.487


  3 in total

Review 1.  Narrative review on endovascular techniques for left subclavian artery revascularization during thoracic endovascular aortic repair and risk factors for postoperative stroke.

Authors:  Mario D'Oria; Kevin Mani; Randall DeMartino; Martin Czerny; Konstantinos P Donas; Anders Wanhainen; Sandro Lepidi
Journal:  Interact Cardiovasc Thorac Surg       Date:  2021-05-10

2.  Actual incidence of cerebral infarction after thoracic endovascular aortic repair: a magnetic resonance imaging study.

Authors:  Sohsyu Kotani; Yoshito Inoue; Naohiko Oki; Hideki Yashiro; Takashi Hachiya
Journal:  Interact Cardiovasc Thorac Surg       Date:  2022-01-18

Review 3.  Role of Endoluminal Techniques in the Management of Chronic Type B Aortic Dissection.

Authors:  Konstantinos Spanos; Tilo Kölbel
Journal:  Cardiovasc Intervent Radiol       Date:  2020-06-29       Impact factor: 2.740

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.