Literature DB >> 30569791

The Reliability and Validity of the PowerTap P1 Power Pedals Before and After 100 Hours of Use.

James Wright, Thomas Walker, Scott Burnet, Simon A Jobson.   

Abstract

PURPOSE: To (1) evaluate agreement between the PowerTap P1 (P1) pedals and the Lode Excalibur Sport cycle ergometer, (2) investigate the reliability of the P1 pedals between repeated testing sessions, and (3) compare the reliability and validity of the P1 pedals before (P10) and after (P1100) ∼100 h of use.
METHODS: Ten participants completed four 5-min submaximal cycling bouts (100, 150, 200, and 250 W), a 2-min time trial, and two 10-s all-out sprints on 2 occasions. This protocol was repeated after 15 mo and ∼100 h of use.
RESULTS: Significant differences were seen between the P10 pedals and the Lode Excalibur Sport at 100 W (P = .006), 150 W (P = .006), 200 W (P = .001), and 250 W (P = .006) and during the all-out sprints (P = .020). After ∼100 h of use, the P1100 pedals did not significantly differ from the Lode Excalibur Sport at 100 W (P = .799), 150 W (P = .183), 200 W (P = .289), and 250 W (P = .183), during the 2-min time trial (P = .583), or during the all-out sprints (P = .412). The coefficients of variation for the P10 and P1100 ranged from 0.6% to 1.3% and 0.5% to 2.0%, respectively, during the submaximal cycling bouts.
CONCLUSION: The P1 pedals provide valid data after ∼100 h of laboratory use. Furthermore, the pedals provide reliable data during submaximal cycling, even after prolonged use.

Entities:  

Keywords:  ergometer; field testing; laboratory testing; power meter

Mesh:

Year:  2019        PMID: 30569791     DOI: 10.1123/ijspp.2018-0563

Source DB:  PubMed          Journal:  Int J Sports Physiol Perform        ISSN: 1555-0265            Impact factor:   4.010


  5 in total

Review 1.  Using Field Based Data to Model Sprint Track Cycling Performance.

Authors:  Hamish A Ferguson; Chris Harnish; J Geoffrey Chase
Journal:  Sports Med Open       Date:  2021-03-16

2.  Are the Assioma Favero Power Meter Pedals a Reliable Tool for Monitoring Cycling Power Output?

Authors:  Víctor Rodríguez-Rielves; José Ramón Lillo-Beviá; Ángel Buendía-Romero; Alejandro Martínez-Cava; Alejandro Hernández-Belmonte; Javier Courel-Ibáñez; Jesús G Pallarés
Journal:  Sensors (Basel)       Date:  2021-04-15       Impact factor: 3.576

Review 3.  Caveats and Recommendations to Assess the Validity and Reliability of Cycling Power Meters: A Systematic Scoping Review.

Authors:  Anthony Bouillod; Georges Soto-Romero; Frederic Grappe; William Bertucci; Emmanuel Brunet; Johan Cassirame
Journal:  Sensors (Basel)       Date:  2022-01-05       Impact factor: 3.576

4.  Validity of the Favero Assioma Duo Power Pedal System for Measuring Power Output and Cadence.

Authors:  Almudena Montalvo-Pérez; Lidia B Alejo; Pedro L Valenzuela; Mario Castellanos; Jaime Gil-Cabrera; Eduardo Talavera; Alejandro Lucia; David Barranco-Gil
Journal:  Sensors (Basel)       Date:  2021-03-24       Impact factor: 3.576

5.  Integrated Physiological, Biomechanical, and Subjective Responses for the Selection of Assistive Level in Pedelec Cycling.

Authors:  Sheng-Chieh Yang; Yun-Ju Lee
Journal:  Front Physiol       Date:  2021-12-08       Impact factor: 4.566

  5 in total