Abstract
BACKGROUND: The aim of this study was to analyze the surface roughness of yttrium stabilized tetragonal polycrystalline zirconia (Y-TZP) ceramics after different laser treatments (CO2, ER: YAG).Entities:
Keywords: CO2 laser; Er: YAG laser; Profilometry; SEM; Sandblasting; Surface roughness; Y-TZP
Mesh:
Substances:
Year: 2018 PMID: 30567536 PMCID: PMC6300027 DOI: 10.1186/s12903-018-0688-y
Source DB: PubMed Journal: BMC Oral Health ISSN: 1472-6831 Impact factor: 2.757
Fig. 1Forty-eight yitriyum stabilized tetragonal polycryistalin zirconia ceramic specimens were prepared
Groups and surface treatments
| Groups | Surface Treatments |
|---|---|
| Group C | Control group, specimens which were untreated. |
| Group S | Specimens were sandblasted with 50-μm Al2O3 powder (Korox 50, Bego, Germany) at 2.8 bar for 15 s through a nozzle distance of 10 mm. |
| Group 3 W | CO2 laser: the applied energy level was 382w/cal 3 W. |
| Group 4 W | CO2 laser: the applied energy level was 509w/cal 4 W. |
| Group 150SP | Er:YAG laser: the applied energy level was 150 mJ with 10-Hz frequency for 45 s. The pulse width 100 μS. |
| Group 150SSP | Er:YAG laser: the applied energy level was 150 mJ with 10-Hz frequency for 45 s. The pulse width 300 μS. |
| Group 300SP | Er:YAG laser: the applied energy level was 150 mJ with 10-Hz frequency for 45 s. The pulse width 300 μS. |
| Group 300SSP | Er:YAG laser: the applied energy level was 300 mJ with 10-Hz frequency for 45 s. The pulse width 300 μS. |
Fig. 2The application tip was moved from bottom to top and maintained in slight contact with the zirconia surface
Mean surface roughness (Ra) values and standard deviations (SD) of the groups
| Groups | N | Mean Ra (μm) | SD |
|
|---|---|---|---|---|
| Group C | 6 | 0.102c | ,034 | |
| Group S | 6 | 0.876a | ,067 | |
| Group 150SP | 6 | 0.102c | ,023 | |
| Group 150SSP | 6 | 0.140c | ,035 | |
| Group 300SP | 6 | 0.110c | ,032 | |
| Group 300SSP | 6 | 0.121c | ,021 | |
| Group 3 W | 6 | 0.158c | ,030 | |
| Group 4 W | 6 | 0.622b | ,177 | |
| Total | 48 | 0.279 | ,290 |
Different letters indicate statistically difference (p<.001)
Fig. 3SEM photographs of study groups at magnification of X500 roughened areas for CO2 and micro cracks for ER-YAG laser were shown with arrows