| Literature DB >> 30565173 |
Jihye Kim1, Kihwan Choi2, Doo Soo Chung3.
Abstract
Single-drop microextraction (SDME) and large-volume sample stacking using an electroosmotic flow pump (LVSEP) were coupled with capillary electrophoresis/mass spectrometry (CE/MS) for sample cleanup and preconcentration. Without filtration or centrifugation of a soil sample containing debris, SDME using a pentanol acceptor drop was directly applied to the sample. After SDME, a large volume of the enriched pentanol extract was injected and further concentrated by LVSEP. For the drop formation in SDME and the sample matrix removal in LVSEP, a run buffer vial was temporarily placed to the electrospray tip, without any physical modification of the CE/MS interface. This method enabled the double preconcentration by SDME and LVSEP, achieving 600~1300-fold enrichments of anionic analytes including pesticide and herbicide compounds to provide limits of detection in the range of 0.4~0.8 ppb in soil. Graphical abstract ᅟ.Entities:
Keywords: Capillary electrophoresis-/mass spectrometry (CE/MS); Large-volume sample stacking using an electroosmotic flow pump (LVSEP); Sample preparation; Single-drop microextraction (SDME); Soil
Year: 2018 PMID: 30565173 DOI: 10.1007/s00216-018-1535-3