What is the best fruit juice to use as a negative oral contrast agent in magnetic resonance cholangiopancreatography?

M Renzulli1, M Biselli2, E Fabbri3, D Caretti4, A Sergenti5, F Modestino5, F A Giannone6, M Storchi6, L Pierotti3, R Golfieri5.   

Abstract

AIM: To identify, in vitro, the best fruit juice to use as oral contrast agent in magnetic resonance cholangiopancreatography (MRCP) and to test, in vivo, the best natural juice and the new parameters in MRCP sequences identified in vitro.
MATERIALS AND METHODS: The in vitro evaluations consisted of measuring the T2 values of a pure solution of manganese (Mn) and iron (Fe) at different concentrations, measuring the content of Mn and Fe in five commercial juices and their T2 relaxation times, and identifying the optimal juice dilution for suppressing the gastrointestinal fluid signal. The new parameters of MRCP sequences were tested in vivo.
RESULTS: Manganese alone strongly influenced the shortening of the T2 values (p=0.004). The T2 value with an echo time (TE) of ≥1,000 ms enabled sufficient intestinal fluid suppression in the case of high juice dilution. A flip angle of 90° maximised the differences between the high signal from static fluids, such as the bile and the fluid in the gastrointestinal tract, using fast imaging employing steady-state acquisition (FIESTA) sequences (p<0.001).
CONCLUSION: The shortening of the T2 relaxation time depended only on the Mn concentration. All the commercial juices had an Mn concentration sufficient to suppress the gastrointestinal fluid signal using long TE sequences. The oral ingestion of commercial juice before MRCP was enough to suppress the signal from the gastrointestinal fluids, regardless of its dilution after ingestion. When using FIESTA sequences, a flip angle of 90° allowed the best suppression of gastrointestinal fluid signals.
Copyright © 2018 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

Entities:  

Year:  2018        PMID: 30554806     DOI: 10.1016/j.crad.2018.11.005

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  4 in total

1.  Not only manganese, but fruit component effects dictate the efficiency of fruit juice as an oral magnetic resonance imaging contrast agent.

Authors:  Giulia Licciardi; Domenico Rizzo; Enrico Ravera; Marco Fragai; Giacomo Parigi; Claudio Luchinat
Journal:  NMR Biomed       Date:  2021-09-30       Impact factor: 4.478

2.  Optimization of pineapple juice amount used as a negative oral contrast agent in magnetic resonance cholangiopancreatography.

Authors:  Matteo Renzulli; Daniele Caretti; Irene Pettinari; Maurizio Biselli; Stefano Brocchi; Alessandro Sergenti; Nicolò Brandi; Rita Golfieri
Journal:  Sci Rep       Date:  2022-01-11       Impact factor: 4.379

3.  Inguinal ureter herniation evaluated with magnetic resonance imaging: a case report.

Authors:  Matteo Renzulli; Guido Marzocchi; Giulio Vara; Beniamino Corcioni; Anna Maria Ierardi; Caterina Gaudiano; Rita Golfieri
Journal:  J Med Case Rep       Date:  2020-10-27

4.  A New Quantitative Classification of the Extrahepatic Biliary Tract Related to Cystic Duct Implantation.

Authors:  Matteo Renzulli; Stefano Brocchi; Giovanni Marasco; Daniele Spinelli; Caterina Balacchi; Massimo Barakat; Irene Pettinari; Rita Golfieri
Journal:  J Gastrointest Surg       Date:  2020-12-02       Impact factor: 3.452

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.