Literature DB >> 30547707

Intravascular Ultrasound-Assisted Endovascular Treatment of Mesenteric Malperfusion in a Multichannel Aortic Dissection With Full True Lumen Collapse.

Baolei Guo1, Daqiao Guo1, Zhenyu Shi1, Zhihui Dong1, Weiguo Fu1.   

Abstract

PURPOSE: To describe endovascular treatment of mesenteric malperfusion in a multichannel aortic dissection (MCAD) with full true lumen (TL) collapse following thoracic endovascular aortic repair (TEVAR). CASE REPORT: A 54-year-old man presented with chronic mesenteric ischemia and a previous TEVAR for MCAD complicated by superior mesenteric artery (SMA) malperfusion. Computed tomography angiography (CTA) demonstrated a 3-channel aortic dissection with a "false-true-false" configuration. The SMA was malperfused through the collapsed TL. CTA also showed a secondary entry tear, measuring 18 mm in diameter, at the end of the previous endograft. Direct open surgery or endovascular revascularization of the SMA was not feasible. A plan was devised to improve SMA perfusion by increasing the TL inflow. With the assistance of intravascular ultrasound (IVUS), an endograft was placed through one false lumen in the abdominal aorta and through the TL in the descending thoracic aorta to seal the secondary entry tear. Symptoms of mesenteric ischemia resolved 2 days after the procedure. At 1 year, he is asymptomatic, has gained weight, and has improved SMA perfusion and remodeling of the 3-channel dissection on CTA.
CONCLUSION: IVUS imaging can help evaluate the complex hemodynamics of MCAD. Patient-specific endovascular treatment of MCAD with mesenteric malperfusion seems to be a feasible bailout alternative treatment for urgent, complex cases without reconstruction options.

Entities:  

Keywords:  aortic dissection; endograft; endovascular repair; intestinal ischemia; intravascular ultrasound; malperfusion syndrome; stent-graft; superior mesenteric artery; thoracic endovascular aortic repair; true lumen; type B aortic dissection

Year:  2018        PMID: 30547707     DOI: 10.1177/1526602818815821

Source DB:  PubMed          Journal:  J Endovasc Ther        ISSN: 1526-6028            Impact factor:   3.487


  2 in total

1.  Total endovascular repair of an intraoperative stent-graft deployed in the false lumen of Stanford type A aortic dissection: A case report.

Authors:  Xu-Ran Li; Yuan-Hao Tong; Xiao-Qiang Li; Chang-Jian Liu; Chen Liu; Zhao Liu
Journal:  World J Clin Cases       Date:  2020-03-06       Impact factor: 1.337

2.  ALDH2 knockout protects against aortic dissection.

Authors:  Chentao Luo; Bing Zhou; Yong Cui; Zhifang Liu; Shuwei Wang
Journal:  BMC Cardiovasc Disord       Date:  2022-10-13       Impact factor: 2.174

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.