Literature DB >> 30547246

Efficiency and complications of Woven EndoBridge (WEB) devices for treatment of larger, complex intracranial aneurysms-a single-center experience.

Zaid Khalid1, Wilhelm Sorteberg2, Bård Nedregaard3, Angelika Sorteberg4,2.   

Abstract

BACKGROUND: Several recently published multicenter studies have reported high treatment feasibility, high safety, and good 6-month to 1-year efficiency when treating smaller intracranial aneurysms (IA) with WEB deployment. The purpose of the study was to evaluate the long-term efficiency and complications related to WEB treatment of larger, complex intracranial aneurysms in a small single-center cohort.
METHODS: Patients with ruptured and unruptured IA were treated with WEB devices; data were collected prospectively and analyzed retrospectively. The study evaluates complications and clinical and radiological findings at immediate and last available follow-up.
RESULTS: The study included 16 patients with 16 aneurysms and a median follow-up time of 36 months, range 13-49 months; 9/16 were females. Median age 59 with range 39-71 years. Mean aneurysm size 11.3 ± 1.7 mm, predominant location at the basilar artery bifurcation and anterior communicating artery. Three out of sixteen IAs were ruptured. Even though 75% of the IAs were immediately occluded completely, retreatment was eventually necessary in 7/15 (46.7%). Increasing neck remnants and recurrences were mainly observed past 1-year follow-up. The WEB device showed modifications over time, with six devices showing signs of compression in the long term. There was one fatality due to aneurysm rupture after 4 years.
CONCLUSIONS: The long-term efficiency of WEB deployment in larger, complex aneurysms is low with about half of the cases needing at least one retreatment. A large fraction of WEB collapse past 1-year follow-up.

Entities:  

Keywords:  Endovascular treatment; Intracranial aneurysms; WEB

Mesh:

Year:  2018        PMID: 30547246     DOI: 10.1007/s00701-018-3752-0

Source DB:  PubMed          Journal:  Acta Neurochir (Wien)        ISSN: 0001-6268            Impact factor:   2.216


  3 in total

1.  A systematic review and meta-analysis of Woven EndoBridge single layer for treatment of intracranial aneurysms.

Authors:  Sbt van Rooij; M E Sprengers; J P Peluso; J Daams; D Verbaan; W J van Rooij; C B Majoie
Journal:  Interv Neuroradiol       Date:  2020-02-06       Impact factor: 1.610

Review 2.  Microsurgical clipping versus newer endovascular techniques in treatment of unruptured anterior communicating artery-complex aneurysms: a meta-analysis and systematic review.

Authors:  F Diana; A Pesce; G Toccaceli; V Muralidharan; E Raz; M Miscusi; A Raco; P Missori; S Peschillo
Journal:  Neurosurg Rev       Date:  2021-10-07       Impact factor: 3.042

3.  Results of the pToWin Study: Using the pCONUS Device for the Treatment of Wide-Neck Intracranial Aneurysms.

Authors:  Marta Aguilar Pérez; Hans Henkes; Wiebke Kurre; Carlos Bleise; Pedro Nicolás Lylyk; Javier Lundquist; Francis Turjman; Hanan Alhazmi; Christian Loehr; Stephan Felber; Hannes Deutschmann; Stephan Lowens; Luigi Delehaye; Markus Möhlenbruch; Jörg Hattingen; Pedro Lylyk
Journal:  J Clin Med       Date:  2022-02-08       Impact factor: 4.241

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.