Literature DB >> 30546648

Low-pressure cardiac tamponade: A case report.

Jorge A Restrepo1, Gianfranco Martinis1, Guillermo Diego1, Natalia Lorenzo1, Fernando Rivero1, Rio Aguilar1.   

Abstract

A 57-year-old woman presented with a large idiopathic pericardial effusion with subsequent cardiac tamponade, in whom the intrapericardial pressure measured by pericardiocentesis was not elevated. The patient did not present with the classical clinical features of cardiac tamponade, requiring echocardiographic follow-up to make accurate diagnosis and treatment. This entity called low-pressure cardiac tamponade has been diagnosed anecdotally being an insidious condition that requires a high degree of suspicion. <Learning objective: Low-pressure cardiac tamponade is a clinical condition whose clinical diagnosis is highly difficult due to the dramatic loss of sensitivity of the classical clinical findings (dyspnea, tachycardia, hypotension, central venous pressure, and paradoxical pulse), making the diagnosis challenging. It requires a high index of suspicion at the echocardiographic study moment, and as in the classic cardiac tamponade many cases eventually require pericardiocentesis for confirmation and treatment.>.

Entities:  

Keywords:  Cardiac tamponade; Echocardiographic; Pericardial effusion; Pericardiocentesis

Year:  2016        PMID: 30546648      PMCID: PMC6283010          DOI: 10.1016/j.jccase.2016.03.005

Source DB:  PubMed          Journal:  J Cardiol Cases        ISSN: 1878-5409


  5 in total

1.  Left ventricular diastolic collapse in low-pressure cardiac tamponade.

Authors:  S K Dwivedi; R Saran; V S Narain
Journal:  Clin Cardiol       Date:  1998-03       Impact factor: 2.882

2.  Low pressure cardiac tamponade: diagnosis facilitated by Doppler echocardiography.

Authors:  S N Hayes; W K Freeman; B J Gersh
Journal:  Br Heart J       Date:  1990-02

3.  Low-pressure cardiac tamponade.

Authors:  C M Boltwood; P Y Lee; C Tei; P M Shah
Journal:  N Engl J Med       Date:  1983-09-15       Impact factor: 91.245

4.  Low-pressure cardiac tamponade.

Authors:  E M Antman; V Cargill; W Grossman
Journal:  Ann Intern Med       Date:  1979-09       Impact factor: 25.391

5.  Low-pressure cardiac tamponade: clinical and hemodynamic profile.

Authors:  Jaume Sagristà-Sauleda; Juan Angel; Antonia Sambola; Joan Alguersuari; Gaietà Permanyer-Miralda; Jordi Soler-Soler
Journal:  Circulation       Date:  2006-08-21       Impact factor: 29.690

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.