Extraction of a trapped pacemaker lead in a pacemaker-dependent patient.

Alexander Kypta1, Hermann Blessberger1, Juergen Kammler1, Thomas Lambert1, Michael Lichtenauer2, Clemens Steinwender1.   

Abstract

A 47-year-old female with a dual chamber pacemaker was referred to our institution for transvenous lead removal because of suspected pocket infection. The history of this patient started in 2002 with a tricuspid valve endocarditis. Therefore, the patient had tricuspid valve repair that yielded a poor outcome. The patient received biological tricuspid valve in 2006. Due to postoperative total atrioventricular-block a DDDR device was implanted. The biological valve degenerated and thus was replaced by a mechanical one in 2014. During this valve implantation the atrial lead was removed and the ventricular lead was trapped by the mechanical valve between the native tricuspid valve annulus of the right ventricle and the outer ring of the mechanical valve. Three months after the last revision the patient developed signs of inflammation. The pocket was opened and a swab test proved positive for Staphylococcus epidermidis. After disinfection with iodine solution the pacemaker was placed under the pectoralis muscle. However, during the following 3 months the patient suffered from swelling over the pacemaker pocket and severe pain. In awareness of the previous history and the clinical symptoms we decided to implant a new pacemaker system on the left side and explant the infected system on the right side. <Learning objective: Pocket infections always require system explantation. Simultaneous explantation of an infected system and implantation of a new system within the same session is not recommended but was necessary in this case. Even complex lead extraction like this one can be successfully performed applying the appropriate tools (locking stylet, Evolution device, Cook Intravascular Inc., Leechburg, PA, USA).>.

Entities:  

Keywords:  Extraction; Mechanical valve; Trapped pacemaker lead

Year:  2015        PMID: 30546612      PMCID: PMC6280686          DOI: 10.1016/j.jccase.2015.10.011

Source DB:  PubMed          Journal:  J Cardiol Cases        ISSN: 1878-5409


  7 in total

1.  Pathways for training and accreditation for transvenous lead extraction: a European Heart Rhythm Association position paper.

Authors:  J C Deharo; M G Bongiorni; A Rozkovec; F Bracke; P Defaye; I Fernandez-Lozano; P G Golzio; B Hansky; C Kennergren; A S Manolis; P Mitkowski; E S Platou
Journal:  Europace       Date:  2012-01       Impact factor: 5.214

2.  Complication rates associated with pacemaker or implantable cardioverter-defibrillator generator replacements and upgrade procedures: results from the REPLACE registry.

Authors:  Jeanne E Poole; Marye J Gleva; Theofanie Mela; Mina K Chung; Daniel Z Uslan; Richard Borge; Venkateshwar Gottipaty; Timothy Shinn; Dan Dan; Leon A Feldman; Hanscy Seide; Stuart A Winston; John J Gallagher; Jonathan J Langberg; Kevin Mitchell; Richard Holcomb
Journal:  Circulation       Date:  2010-10-04       Impact factor: 29.690

3.  Transvenous lead extraction: Heart Rhythm Society expert consensus on facilities, training, indications, and patient management: this document was endorsed by the American Heart Association (AHA).

Authors:  Bruce L Wilkoff; Charles J Love; Charles L Byrd; Maria Grazia Bongiorni; Roger G Carrillo; George H Crossley; Laurence M Epstein; Richard A Friedman; Charles E H Kennergren; Przemyslaw Mitkowski; Raymond H M Schaerf; Oussama M Wazni
Journal:  Heart Rhythm       Date:  2009-05-22       Impact factor: 6.343

Review 4.  HRS/EHRA expert consensus on the monitoring of cardiovascular implantable electronic devices (CIEDs): description of techniques, indications, personnel, frequency and ethical considerations.

Authors:  Bruce L Wilkoff; Angelo Auricchio; Josep Brugada; Martin Cowie; Kenneth A Ellenbogen; Anne M Gillis; David L Hayes; Jonathan G Howlett; Josef Kautzner; Charles J Love; John M Morgan; Silvia G Priori; Dwight W Reynolds; Mark H Schoenfeld; Panos E Vardas
Journal:  Heart Rhythm       Date:  2008-06       Impact factor: 6.343

5.  Temporal trends in permanent pacemaker implantation: a population-based study.

Authors:  Daniel Z Uslan; Imad M Tleyjeh; Larry M Baddour; Paul A Friedman; Sarah M Jenkins; Jennifer L St Sauver; David L Hayes
Journal:  Am Heart J       Date:  2008-02-19       Impact factor: 4.749

Review 6.  QTc interval in the assessment of cardiac risk.

Authors:  Hanne Elming; Bente Brendorp; Lars Køber; Najia Sahebzadah; Christian Torp-Petersen
Journal:  Card Electrophysiol Rev       Date:  2002-09

7.  Larger interventricular conduction time enhances mechanical response to resynchronization therapy.

Authors:  Luigi Padeletti; Paolo Pieragnoli; Giuseppe Ricciardi; Laura Perrotta; Alessandro P Perini; Gino Grifoni; Ilaria Ricceri; Margherita Padeletti; Vincenzo Lionetti; Sergio Valsecchi
Journal:  Pacing Clin Electrophysiol       Date:  2013-01-10       Impact factor: 1.976

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.