Literature DB >> 30546206

Comparative evaluation of bond strength of self-adhering flowable composites to the dentin prepared with different burs: An in vitro study.

Anithakumari Rangappa1, Jyothi Srinivasulu1, Vikram Rangaswamy1, Sudhanva Eregowda1, Vijayalakshmi Lakshminarasimhaiah1, Usha Lingareddy1.   

Abstract

AIM: The aim of this study was to evaluate the shear bond strength (SBS) of self-adhering flowable composites on the dentinal surface prepared with carbide and diamond burs.
MATERIALS AND METHODS: A total of 64 extracted mandibular molars were mounted on acrylic resin blocks, and the coronal part of the dentin was exposed and polished. Then, they were divided into Group 1 and Group 2 for carbide and diamond bur preparation, respectively. Two teeth in each group were evaluated under scanning electron microscope, ×500, to view the surface changes following the bur preparation. The remaining teeth were subdivided into Groups A, B, and C to be restored with Constic, Dyad™-flow, and Tetric N Flow composites, respectively. Then, the specimens were stored in distilled water at 37°C for 24 h, and then subjected to universal testing machine to evaluate the SBS and viewed under light stereomicroscope to evaluate the type of failure. STATISTICAL ANALYSIS: SPSS version 22 (IBM Corp) for Windows was used for statistical analysis. The values were subjected to ANOVA followed by Bonferroni post hoc analysis. The values between the groups were analyzed using Student's unpaired t-test.
RESULTS: Statistically significant differences in the SBS values were seen between Groups A and C (P < 0.001) and Groups B and C (P < 0.001). Statistically significant differences were seen in SBS values of Dyad-flow (Group B) (P < 0.004) and Tetric N flow (P < 0.007) for surfaces prepared with carbide and diamond burs.
CONCLUSION: It was concluded that the SBS of Tetric-N Flow was higher than that of the experimental groups of Constic and Dyad-flow. Dentinal surface preparation with carbide bur resulted in higher SBS for Tetric N Flow and Dyad-flow but not for Constic.

Entities:  

Keywords:  Carbide bur; dentinal surface preparation; diamond bur; self-adhering flowable composite; shear bond strength

Year:  2018        PMID: 30546206      PMCID: PMC6249948          DOI: 10.4103/JCD.JCD_71_18

Source DB:  PubMed          Journal:  J Conserv Dent        ISSN: 0972-0707


INTRODUCTION

Composite resin achieves esthetically and clinically acceptable restoration with minimal tooth preparation. Starting from the introduction of acid etching by Michael Buonocore and introduction of BISGMA by Raphael Bowen 50 years back, the material has undergone significant changes in terms of formulation and clinical techniques. In the mid-1990s, flowable composite was introduced into the market.[1] Flowable composites have the advantage of easy handling, lesser polymerization shrinkage, better marginal adaptation, and better wear resistance, thus indicated in preventive resin, small Class I, minimally invasive Class II proximal box, small Class III and Class V restorations.[2] However, composites have to be combined with good bonding agent for successful results. Dentin bonding is further complicated by the formation of the smear layer which is created when dentin is cut or ground. Surface preparation of the substrate with different rotary instruments has also been shown to have an effect in the bonding between adhesive and dentin.[34]

MATERIALS AND METHODS

A total of 64 extracted third molars were collected and stored in normal saline. The teeth were mounted on acrylic resin blocks and the coronal one-third of the crown was sectioned exposing the flat dentinal surface and was polished using 600 grit silicon carbide abrasive paper. Then, the teeth were divided into two groups 1 and 2 of 32 teeth each. The samples of Group 1 were prepared using fissure carbide no. FG8642G (SS White) and those of Group 2 were prepared using coarse taper round end diamond bur SSW-TR13C (SS White). Figure 1 shows dentinal surface prepared with fissure carbide bur and Figure 2 shows dentinal surface prepared with coarse diamond bur. For preparation of every five samples, a new bur was replaced by a high-speed hand piece with air–water spray, with a maximum speed of 3,40,000 rpm and an air pressure of 27 psi. The preparation was carried out for 10 sweeps of the bur in a single direction and a controlled pressure of hand on the dentinal surface. The remaining teeth in each group were subdivided into Group A, Group B, and Group C. In Group A, 0.5 mm thickness of Constic, (DMG, Germany), self-adhering flowable composite resin (SAFC), was dispensed with the aid of the Luer-Lok™ syringe and massaged for 25 s using the supplied brush. Excess, if any, was removed and light cured for 20 s. Then, the material was layered in increments of 2 mm and 1 mm to prepare 3-mm composite discs on the dentinal surface. In Group B, 0.5 mm thickness of Dyad™ flow (Kerr) SAFC was brushed with moderate pressure for 15–20 s to obtain a thin layer, and then the excess material was removed and light cured for 20 s. Then, the material was layered in increments of 2 mm and 1 mm to prepare 3-mm composite discs on the dentinal surface. In Group C, Tetric N Bond (Ivoclar Vivadent) self-etch adhesive was applied on the dentin surface and restored with Tetric N Flow (Ivoclar Vivadent) composite resin to prepare 3-mm disc and light cured for 15 s.
Figure 1

Scanning electron micrograph of dentinal surface prepared with carbide bur

Figure 2

Scanning electron micrograph of dentinal surface prepared with diamond bur

Scanning electron micrograph of dentinal surface prepared with carbide bur Scanning electron micrograph of dentinal surface prepared with diamond bur

Shear bond strength evaluation

The samples were stored in distilled water for 24 h and were subjected to shear bond strength (SBS) test. SBS was evaluated using universal testing machine (Multi test 10i, Indian Institute of Science, Bengaluru, Karnataka, India), with a knife-edged rod of 0.5 mm width at a cross head speed of 1 mm/min applied at the dentin–composite interface parallel to the long axis of the tooth. The bond strength was recorded in Newton (N) and converted into Megapascal (MPa) using the following equation: 1 MPa = 1 N/mm2 Where mm2 is the total surface area of the bonded composite. The Statistical Package for the Social Sciences version 22, IBM Corp, Armonk, IL, Chicago, USA, for Windows, was used for statistical analysis of data using ANOVA followed by Bonferroni post hoc analysis. Comparison of SBS between groups was analyzed using Student's unpaired t-test. Results with P < 0.05 were considered statistically significant. The bond failure modes were evaluated using a light stereomicroscope (Zeiss stereo Discovery. V20) under ×20 magnification and classified as cohesive, adhesive, and mixed failures.

RESULTS

All the three groups in carbide bur (Group 1) preparation showed higher SBS values than the same groups in diamond bur (Group 2) surface preparation. Group C showed the highest SBS value followed by Group B and then Group A. Statistically significant differences in the SBS values were observed between Groups A and C (P < 0.001) and Groups B and C (P < 0.001) as shown in Table 1.
Table 1

Comparison of sheer strength of different restorative materials done under different preparations using ANOVA fld by Bonferroni post hoc analysis

Comparison of sheer strength of different restorative materials done under different preparations using ANOVA fld by Bonferroni post hoc analysis Table 2 shows statistically insignificant difference (P = 0.116) in SBS values of Constic (Group A) for surfaces prepared with carbide (Group 1) and diamond (Group 2) burs, with statistically significant difference (P < 0.004) in SBS values of Dyad flow (Group B) and Tetric N flow (Group C) (P < 0.007) for surfaces prepared with carbide and diamond burs.
Table 2

Comparison of shear strength in Group A, B & C under different conditions using student unpaired t-test

Comparison of shear strength in Group A, B & C under different conditions using student unpaired t-test The higher bond strength values showed predominantly mixed failure, whereas lower bond strength values showed adhesive failure.

DISCUSSION

The clinical outcome of dental restorations bonded to dentine is dependent on the hybridization of adhesive resins into partially demineralized dentine.[5] Any tooth surface preparation with the rotary instrument generates smear layer. Gwinnett has reported that the thickness of the smear layer depends on the type of the bur, the use of water spray, and the speed of the instrument.[6] SAFC combines the etching, bonding, and restorative procedures in a single step, thus simplifying and reducing the chairside time to the clinician and the patient. In this study, two self-adhering flowable composites, Constic and Dyad flow, and one conventional flowable composite, Tetric N Flow, were used to compare the SBS. In this study in carbide fissure group, all the flowable composites gave higher SBS values than that of the diamond group even though it was not statistically significant in Constic group, this is in agreement with the findings of Ogata et al. and Yiu et al.[78] There is micromorphologic difference in dentin cut by diamond and carbide rotary instruments.[910] A thick smear layer containing cut collagen fibers and hydroxyapatite crystallites was created with coarse diamond bur.[611] Thicker smear layer prevents the effective contact between the dentinal tissue and the restorative material, thus poses a challenge for penetration and impregnation of the underlying dentin by adhesive monomers.[1213] Oliveira et al. observed that thicker smear layer interferes with the adhesion capabilities of the self-etching primer, suggesting that thin smear layer created by the carbide bur should be treated with self-etching primer for effective bonding.[14] On the contrary, Rocha et al. and Young et al. reported that use of diamond burs for dentinal surface preparation resulted in higher bond strength.[1516] The SBS values of two self-adhesive flowable composites were lower than that of the Tetric N Flow on the dentine surfaces prepared with both diamond and carbide burs. This is in agreement with the findings of Rubens et al.,[17]İşman et al.,[18] Yuan et al.,[19] and Tuloglu et al.[20] Constic did not show statistically significant values between carbide and diamond surface preparation. Constic contains methacrloxydecyl dihydrogen phosphate (MDP) along with bisphenol A-glycidyl methacrylate, ethoxylated bisphenol A dimethacrylate (EBADMA), urethane dimethacrylate, 2-hydroxy ethyl methacrylate (HEMA), triethylene glycol dimethacrylate (TEGDMA), and 1,6-hexanediol dimethacrylate (HDMA) monomers. MDP monomer holds longer and more hydrophobic spacer chains compared to the GPDM monomer present in Dyad-Flow. MDP was found to form stable 10-MDP-calcium salts without causing strong decalcification, which leads to strong chemical bonding with hydroxyapatite.[21] Since there is no difference in bond strength between carbide and diamond groups, it is presumed that the thickness of the smear layer created by the burs does not influence the bonding of Constic to the dentin. Dyad-Flow showed statistically significant higher values of SBS for carbide burs than diamond burs. Dyad-Flow contains GPDM adhesive monomer, a phosphate functional group which has an acidic phosphate group for etching the tooth structure and two methacrylate groups for co-polymerization with other methacrylate monomers to provide increased cross-linking density and enhanced mechanical strength for the polymerized adhesive. Dyad-Flow bonds to the tooth in two ways: primarily through the interaction of phosphate functional group with calcium ions of the tooth and secondarily through micromechanical bonding as a result of an interpenetrating network formed between the polymerized monomer of Dyad-Flow and collagen fibers of dentin.[22] The etching potential of the functional group may not be sufficient enough to penetrate the thick, coarse smear layer resulted after diamond bur preparation, thus influencing the bond strength, which is in agreement with the findings of Isman et al.[18] Bond strength tests have been considered to provide a quantitative assessment of adhesion of a material to a substrate. SBS tests are inadequate for the evaluation of the bond strength to dental hard tissues as clinically unrealistic stress is produced within the reaction zone. In spite of its drawback, shear bond tests have been widely used to evaluate the bonding ability of adhesive materials to dental structure.[2324]

CONCLUSION

Within the limitations of this study, it can be concluded that self-adhering flowable composites could not achieve comparable bond strength compared to the traditional flowable composites that are used along with the bonding agent. Constic did not show any difference in the bond strength with the dentinal surfaces prepared with tungsten carbide and diamond bur. However, Dyad-Flow and Tetric N Flow showed higher bond strength to the dentinal surface prepared with the tungsten carbide bur than the diamond bur, implying that the bond strength of the adhesive material is material dependent. Further clinical studies are required to confirm the bond strength of these self-adhering flowable composites.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.
  19 in total

Review 1.  Resin composite--state of the art.

Authors:  Jack L Ferracane
Journal:  Dent Mater       Date:  2010-11-18       Impact factor: 5.304

Review 2.  Flowable Resin Composites: A Systematic Review and Clinical Considerations.

Authors:  Kusai Baroudi; Jean C Rodrigues
Journal:  J Clin Diagn Res       Date:  2015-06-01

3.  Evaluation of Microtensile Bond Strength and Microleakage of a Self-adhering Flowable Composite.

Authors:  He Yuan; Mingyang Li; Bin Guo; Yuan Gao; HongLing Liu; Jiyao Li
Journal:  J Adhes Dent       Date:  2015-12       Impact factor: 2.359

4.  Effect of dentinal surface preparation on bond strength of self-etching adhesive systems.

Authors:  Patrícia Itocazo Rocha; Alessandra Bühler Borges; José Roberto Rodrigues; César Augusto Galvão Arrais; Marcelo Giannini
Journal:  Braz Oral Res       Date:  2006-05-22

5.  Effect of bur type and conditioning on the surface and interface of dentine.

Authors:  J A Barros; S I Myaki; J E Nör; M C Peters
Journal:  J Oral Rehabil       Date:  2005-11       Impact factor: 3.837

6.  Clinical relevance of tests on bond strength, microleakage and marginal adaptation.

Authors:  Siegward D Heintze
Journal:  Dent Mater       Date:  2012-08-21       Impact factor: 5.304

7.  Adhesive interfacial characteristics and the related bonding performance of four self-etching adhesives with different functional monomers applied to dentin.

Authors:  Ruirui Wang; Yilin Shi; Tingting Li; Yueping Pan; Yu Cui; Wenwei Xia
Journal:  J Dent       Date:  2017-05-17       Impact factor: 4.379

8.  Effects of diamond bur particle size on dentin bond strength.

Authors:  Yumiko Hosoya; Hiroe Shinkawa; Chikako Suefiji; Kumiko Nozaka; Franklin García-Godoy
Journal:  Am J Dent       Date:  2004-10       Impact factor: 1.522

9.  Bonding to intact dentin.

Authors:  N Nakabayashi; Y Saimi
Journal:  J Dent Res       Date:  1996-09       Impact factor: 6.116

10.  Bond strength of resin modified glass ionomer cement to primary dentin after cutting with different bur types and dentin conditioning.

Authors:  Rebeca Di Nicoló; Luciana Keiko Shintome; Silvio Issáo Myaki; Marcos Paulo Nagayassu
Journal:  J Appl Oral Sci       Date:  2007-10       Impact factor: 2.698

View more
  1 in total

1.  Effect of mechanical alteration of enamel surface on shear bond strength of different bonding techniques.

Authors:  Janvi Talan; Sachin Gupta; Vineeta Nikhil; Shikha Jaiswal
Journal:  J Conserv Dent       Date:  2020-11-05
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.