| Literature DB >> 30546184 |
Zsolt Varga1, Adrian Nicholl1, Erich Hrnecek1, Maria Wallenius1, Klaus Mayer1.
Abstract
The paper describes the age (production date) determination of uranium reference materials using the 231Pa/235U ratio. Direct addition of 237Np in secular equilibrium with its 233Pa daughter was chosen instead of the regular milking of 237Np to avoid possible loss of Pa. Sample preparation consists of a fast, one-step procedure. The developed method using ICP-MS for the measurement of 231Pa is more precise than alpha spectrometry and is applicable for freshly produced low-enriched uranium materials. The measured ages are in good agreement with the reported production dates, thus the 231Pa/235U chronometer can be applied for validation of 230Th/234U in nuclear forensics and safeguards.Entities:
Keywords: Age determination; Nuclear forensics; Nuclear safeguards; Protactinium measurement; Uranium
Year: 2018 PMID: 30546184 PMCID: PMC6267122 DOI: 10.1007/s10967-018-6247-9
Source DB: PubMed Journal: J Radioanal Nucl Chem ISSN: 0236-5731 Impact factor: 1.371
Fig. 1Elution profile of U and Pa using different resins
Fig. 2A schematic of the age determination from the 231Pa/235U ratio
Fig. 3Measurement results of the 237Np spike concentration
Fig. 4Typical ICP-MS spectrum (U100 #1). The shown mass regions are the selected masses for measurement (m/z of 231Pa, 233Pa, 234U and 237Np). Major U isotopes were not measured due to the possible high signal
Measured 231Pa/235U mass ratios and production dates
| Sample | 231Pa/235U mass ratio | Standard uncertainty | 231Pa/235U model age (year) | Expanded uncertainty (year, | Measured 231Pa/235U model production date |
|---|---|---|---|---|---|
| CRM 125-A #1 | 2.278 × 10−8 | 4.2 × 10−10 | 23.54 | 0.88 | 26 December 1994 |
| CRM 125-A #2 | 2.269 × 10−8 | 3.2 × 10−10 | 23.45 | 0.67 | 27 January 1995 |
| IRMM1000 #1 | 5.926 × 10−9 | 1.2 × 10−10 | 6.12 | 0.24 | 27 May 2012 |
| IRMM1000 #1 | 6.006 × 10−9 | 1.0 × 10−10 | 6.21 | 0.21 | 24 April 2012 |
| U100 #1 | 5.619 × 10−8 | 7.5 × 10−10 | 58.1 | 1.6 | 03 June 1960 |
| U100 #2 | 5.813 × 10−8 | 9.6 × 10−10 | 60.1 | 2.0 | 04 June 1958 |
| U630 #1 | 2.815 × 10−8 | 4.0 × 10−10 | 29.09 | 0.83 | 07 June 1989 |
| U630 #2 | 2.805 × 10−8 | 3.8 × 10−10 | 28.99 | 0.79 | 14 July 1989 |
Fig. 5231Pa/235U model production date of the measured U samples. In a, b, d the certified production dates by the 230Th/234U ratio are also given