Literature DB >> 30540364

Safety and Efficacy of a New Phakic Posterior Chamber IOL for Correction of Myopia: 3 Years of Follow-up.

Viraj Vasavada, Samaresh Srivastava, Shail A Vasavada, Aditya Sudhalkar, Abhay R Vasavada, Vaishali A Vasavada.   

Abstract

PURPOSE: To evaluate the outcomes of a new posterior chamber phakic intraocular lens (IPCL; Care Group, Baroda, India) to correct myopia.
METHODS: This prospective, observational case series included 30 eyes undergoing implantation of the IPCL for high myopia (> -8.00 diopters [D]). Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, vault, endothelial cell loss, and adverse events were evaluated 3 years after implantation of the IPCL for high myopia.
RESULTS: The mean spherical equivalent decreased from -16.50 ± 5.62 D preoperatively to -0.89 ± 1.27 D at 3 years. The mean UDVA and CDVA were 0.38 ± 0.21 and 0.24 ± 0.09 logMAR. No eye lost any lines and 49% of eyes gained one line or more of CDVA. One eye (3.3%) developed anterior subcapsular cataract, but did not require cataract surgery at 3 years of follow-up. Two eyes (6.6%) developed a mild transient increase in intraocular pressure, which required topical medication only for 3 months. The percentage of endothelial cell loss at 3 years was 9.73% ± 6.72%. The IPCL vault tended to reduce with time, from a mean of 626.66 ± 188.98 μm at 1 month to 540.22 ± 210.76 μm at 3 years. No vision-threatening complications occurred.
CONCLUSIONS: Implantation of the new posterior chamber phakic IOL is an effective alternative to correct high myopia, showing good outcomes at 3 years. [J Refract Surg. 2018;34(12):817-823.]. Copyright 2018, SLACK Incorporated.

Entities:  

Mesh:

Year:  2018        PMID: 30540364     DOI: 10.3928/1081597X-20181105-01

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  11 in total

Review 1.  Analysis of perioperative problems related to intraocular Implantable Collamer Lens (ICL) implantation.

Authors:  Hao Zhang; Rui Gong; Xiaolan Zhang; Yingping Deng
Journal:  Int Ophthalmol       Date:  2022-06-22       Impact factor: 2.029

2.  A Novel Concept of Correcting Presbyopia: First Clinical Results with a Phakic Diffractive Intraocular Lens.

Authors:  Ruediger Schmid; Holger Luedtke
Journal:  Clin Ophthalmol       Date:  2020-07-17

3.  Safety and Efficacy of a New Posterior Chamber Phakic Intraocular Lens in Cases of High Myopia: Early Results.

Authors:  Praveen Subudhi; Sweta Patro; Prateek Agarwal; Zahiruddin Khan; B Nageswar Rao Subudhi; Chandan Mekap; Asutosh Padhi
Journal:  Clin Ophthalmol       Date:  2020-10-30

4.  Short-term changes in and preoperative factors affecting vaulting after posterior chamber phakic Implantable Collamer Lens implantation.

Authors:  Qiu-Jian Zhu; Wen-Jing Chen; Wei-Jian Zhu; Hai-Xiang Xiao; Man-Hui Zhu; Lie Ma; You Yuan; E Song
Journal:  BMC Ophthalmol       Date:  2021-05-06       Impact factor: 2.209

5.  Commentary: Expanding indications of newer and economically viable phakic posterior chamber intraocular lens designs.

Authors:  Suresh K Pandey; Vidushi Sharma
Journal:  Indian J Ophthalmol       Date:  2019-07       Impact factor: 1.848

6.  Rotational Stability of a New Posterior Chamber Toric Phakic Intraocular Lens.

Authors:  Dilek Yaşa; Bülent Köse; Alper Ağca
Journal:  J Ophthalmol       Date:  2020-04-09       Impact factor: 1.909

Review 7.  Phakic intraocular lenses: An overview.

Authors:  Soraya M R Jonker; Tos T J M Berendschot; Isabelle E Y Saelens; Noël J C Bauer; Rudy M M A Nuijts
Journal:  Indian J Ophthalmol       Date:  2020-12       Impact factor: 1.848

Review 8.  Myopia in India.

Authors:  Amar Pujari; Sujeeth Modaboyina; Divya Agarwal; Gunjan Saluja; Rajeswari Thangavel; Vaishali Rakheja; Rohit Saxena; Namrata Sharma; Jeewan S Titiyal; Atul Kumar
Journal:  Clin Ophthalmol       Date:  2022-01-20

9.  Evaluation of the anterior chamber angle by anterior segment optical coherence tomography after implantable phakic contact lens implantation in myopic eyes.

Authors:  Mohamed Salah El-Din Mahmoud; Asmaa Anwar Mohamed; Hosny Ahmed Zein
Journal:  Int Ophthalmol       Date:  2022-03-04       Impact factor: 2.029

10.  The Influence of 0.5% Tropicamide on Anterior Segment Parameters With CASIA2 in Emmetropic, Myopic, and Hyperopic Eyes.

Authors:  Feng Lin; Yuliang Wang; Yujia Liu; Xiaomei Qu; Xingtao Zhou
Journal:  Front Physiol       Date:  2022-07-12       Impact factor: 4.755

View more