Literature DB >> 30540362

Outcomes for Hyperopic LASIK With the MEL 90® Excimer Laser.

Dan Z Reinstein, Glenn I Carp, Timothy J Archer, Alexander C Day, Ryan S Vida.   

Abstract

PURPOSE: To report the outcomes of laser in situ keratomileusis (LASIK) for hyperopia using the Triple-A ablation profile with the MEL 90 excimer laser (Carl Zeiss Meditec, Jena, Germany).
METHODS: This retrospective analysis included 1,383 eyes treated by LASIK for hyperopia using the Triple-A ablation profile with the MEL 90 at London Vision Clinic, London, United Kingdom, between September 2013 and December 2016. Inclusion criteria were attempted hyperopic correction of +0.25 diopters (D) or higher and corrected distance visual acuity (CDVA) of 20/40 or better. Patients were observed for 1 year after surgery. Standard outcomes analysis was performed.
RESULTS: One-year data were available for 1,350 (97%) eyes. Mean attempted spherical equivalent refraction (SEQ) was +2.77 ± 1.34 D (range: +0.13 to +6.50 D) and mean cylinder was -0.67 ± 0.66 D (range: 0.00 to -5.00 D). Mean age was 54 ± 11 years (range: 21 to 75 years), and 57% were female. Postoperative spherical equivalent was ±0.50 D in 73% and ±1.00 D in 93% of eyes. Uncorrected distance visual acuity was 20/20 or better in 75% of eyes, relative to 93% with preoperative CDVA of 20/20 or better. One line of CDVA was lost in 17% of eyes and two lines were lost in 0.6% of eyes. There was a clinically insignificant but statistically significant increase (P < .01) in contrast sensitivity at 3 and 6 cycles per degree (cpd) and no change for 12 and 18 cpd.
CONCLUSIONS: LASIK for hyperopia with the MEL 90 excimer laser was found to satisfy accepted criteria for safety, efficacy, and stability. [J Refract Surg. 2018;34(12):799-808.]. Copyright 2018, SLACK Incorporated.

Entities:  

Mesh:

Year:  2018        PMID: 30540362     DOI: 10.3928/1081597X-20181019-01

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  2 in total

1.  Treatment of High Astigmatism with WaveLight Allegretto Eye-Q Excimer Laser Platform.

Authors:  Alma Biscevic; Maja Bohac; Melisa Ahmedbegovic Pjano; Senad Grisevic; Sudi Patel; Ajla Pidro
Journal:  Acta Inform Med       Date:  2019-09

2.  One-Year Visual and Refractive Outcomes following LASIK for Myopia and Myopic Astigmatism with MEL 90 versus Schwind Amaris 750S Excimer Laser: A Comparative Study.

Authors:  Sheetal Brar; Dishitha P Rathod; C R Roopashree; Sri Ganesh
Journal:  J Ophthalmol       Date:  2021-06-25       Impact factor: 1.909

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.