Literature DB >> 30534267

Enhanced stent visualization systems during PCI: A case series and review of literature.

Simone Biscaglia1, Carlo Tumscitz1, Matteo Tebaldi1, Elisa Andrenacci1, Rita Pavasini1, Gianluca Campo1,2, Roberto Ferrari1,2,3.   

Abstract

Enhanced stent visualization systems increase the amount and quality of information during percutaneous coronary interventions. When compared to imaging techniques such as intravascular ultrasound and optical coherence tomography, enhanced stent visualization systems are easy-to-use, as well as time and cost saving. They are useful during stent implantation, overlap, assessment of integrity, and expansion. We review the available data regarding enhanced stent visualization systems and we report 5 cases showing their current applications during percutaneous coronary interventions. <Learning objective: Enhanced stent visualization (ESV) systems are helpful especially during complex percutaneous coronary interventions (PCI). In everyday clinical practice, ESV systems can be used both along with and instead of intracoronary imaging systems. The present case series show the main current applications of ESV systems during complex PCI cases with a brief review of the available data.>.

Keywords:  Complex percutaneous coronary intervention; Enhanced stent visualization system; Intravascular ultrasound; Optical coherence tomography; Stent fracture

Year:  2015        PMID: 30534267      PMCID: PMC6279651          DOI: 10.1016/j.jccase.2015.02.008

Source DB:  PubMed          Journal:  J Cardiol Cases        ISSN: 1878-5409


  14 in total

1.  Successful retrieval of a broken intravascular ultrasound catheter tip from a coronary artery.

Authors:  Atila Iyisoy; Murat Celik; Turgay Celik; Uygar Cagdas Yuksel; Samed Samedli
Journal:  Cardiovasc Revasc Med       Date:  2012-03-28

2.  Circumferential stent fracture: novel detection and treatment with the use of StentBoost.

Authors:  Raghu T Ramegowda; Srinivas B Chikkaswamy; Ashalatha Bharatha; Jayashree Radhakrishna; Geetha B Krishnanaik; Manjunath C Nanjappa; Arunkumar Panneerselvam
Journal:  Tex Heart Inst J       Date:  2012

3.  Enhanced stent visualization: a case series demonstrating practical applications during PCI.

Authors:  Marvin H Eng; Andrew P Klein; Onno Wink; Adam Hansgen; John D Carroll; Joel A Garcia
Journal:  Int J Cardiol       Date:  2009-01-09       Impact factor: 4.164

4.  The utility of stent enhancement to guide percutaneous coronary intervention for bifurcation lesions.

Authors:  Joana D Silva; Xavier Carrillo; Neus Salvatella; Eduard Fernandez-Nofrerias; Oriol Rodriguez-Leor; Josepa Mauri; Antoni Bayes-Genis
Journal:  EuroIntervention       Date:  2013-12       Impact factor: 6.534

Review 5.  Clinical applications of a new Enhanced Stent Imaging technology.

Authors:  Tamim M Nazif; Giora Weisz; Jeffrey W Moses
Journal:  Catheter Cardiovasc Interv       Date:  2013-03-02       Impact factor: 2.692

6.  Evaluating stent optimisation technique (StentBoost®) in a dedicated bifurcation stent (the Tryton™).

Authors:  Zamil Fysal; Thomas Hyde; Edward Barnes; William McCrea; Steve Ramcharitar
Journal:  Cardiovasc Revasc Med       Date:  2014-01-13

7.  StentBoost imaging for the assessment of optimal stent deployment and coverage of side branch ostium in coronary bifurcation intervention.

Authors:  Marek Roik; Dominik Wretowski; Rafał Wolny; Andrzej Łabyk; Maciej Kostrubiec; Piotr Pruszczyk
Journal:  Int J Cardiol       Date:  2014-01-22       Impact factor: 4.164

8.  Usefulness of enhanced stent visualization imaging technique in simple and complex PCI cases.

Authors:  Vivek Mutha; M Asrar Ul Haq; Naveen Sharma; W F den Hartog; William J van Gaal
Journal:  J Invasive Cardiol       Date:  2014-10       Impact factor: 2.022

9.  Impact of StentBoost subtract imaging on patient radiation exposure during percutaneous coronary intervention.

Authors:  Zhigeng Jin; Shengli Yang; Limin Jing; Huiliang Liu
Journal:  Int J Cardiovasc Imaging       Date:  2013-03-03       Impact factor: 2.357

10.  Effect of StentBoost imaging guided percutaneous coronary intervention on mid-term angiographic and clinical outcomes.

Authors:  Dong Joo Oh; Cheol Ung Choi; SunWon Kim; Sung Il Im; Jin Oh Na; Hong Euy Lim; Jin Won Kim; Eung Ju Kim; Seong Woo Han; Seung-Woon Rha; Chang Gyu Park; Hong Seog Seo
Journal:  Int J Cardiol       Date:  2013-01-16       Impact factor: 4.164

View more
  2 in total

Review 1.  BRS implantation in long lesions requiring device overlapping: myth or reality?

Authors:  Simone Biscaglia; Andrea Erriquez; Davide Bernucci; Giulia Bugani; Enrico Favaretto; Gianluca Campo
Journal:  J Thorac Dis       Date:  2017-08       Impact factor: 2.895

2.  A patient with an hourglass shaped fractured coronary stent.

Authors:  Andreas Y Andreou; Angelos Tyrlis
Journal:  Postepy Kardiol Interwencyjnej       Date:  2021-03-26       Impact factor: 1.426

  2 in total