N Große Hokamp1, V C Obmann2, R Kessner2, K R Laukamp2, T Persigehl3, S Haneder3, N Ramaiya4. 1. University Hospitals Cleveland Medical Center, Department of Radiology, Cleveland, OH, USA; Case Western Reserve University, Department of Radiology, Cleveland, OH, USA; University Hospital Cologne, Institute for Diagnostic and Interventional Radiology, Cologne, Germany. Electronic address: nils.grosse-hokamp@uk-koeln.de. 2. University Hospitals Cleveland Medical Center, Department of Radiology, Cleveland, OH, USA; Case Western Reserve University, Department of Radiology, Cleveland, OH, USA. 3. University Hospital Cologne, Institute for Diagnostic and Interventional Radiology, Cologne, Germany. 4. University Hospitals Cleveland Medical Center, Department of Radiology, Cleveland, OH, USA.
Abstract
OBJECTIVES: The well-known boost of iodine associated-attenuation in low-keV virtual monoenergetic images (VMI_low) is frequently used to improve visualization of lesions and structures taking up contrast media. This study aimed to evaluate this concept in reverse. Hence to investigate if increased attenuation within the liver allows for improved visualization of little or not-enhancing lesions. METHODS: A 3D-printed phantom mimicking the shape of a human liver exhibiting a lesion in its center was designed and printed. Both, parenchyma- and lesion-mimic were filled with different solutions exhibiting 80/100/120HU and 0/15/40/60HU, respectively. Further, a total of 74 contrast-enhanced studies performed on a spectral detector CT scanner (SDCT) were included in this retrospective study. Patients had MRI or follow-up proven cysts and/or hypodense metastases. VMI of 40-200 keV as well as conventional images (CI) were reconstructed. ROI were placed in lesion and parenchyma(-mimics) on CI and transferred to VMI. Signal- and contrast-to-noise ratio were calculated (S-/CNR). Further, two radiologists independently evaluated image quality. Data was statistically assessed using ANOVA or Wilcoxon-test. RESULTS: In phantoms, S/CNR was significantly higher in VMI_low. The cyst-mimic in highly attenuating parenchyma-mimic on CI yielded a CNR of 6.4 ± 0.8; using VMI_40 keV, mildly hypodense lesion-mimic in poorly attenuating parenchyma-mimic exhibited a similar CNR (5.8 ± 0.9; p ≤ 0.05). The same tendency was observed in patients (cyst in CI/metastasis in VMI_40 keV: 4.4 ± 1.2/3.9 ± 1.8; p ≤ 0.05). Qualitative analysis indicated a benefit of VMI_40 keV (p ≤ 0.05). CONCLUSIONS: VMI_low from SDCT allow for an improved visualization of hypodense focal liver lesions exploiting the concept of contrast blooming in reverse.
OBJECTIVES: The well-known boost of iodine associated-attenuation in low-keV virtual monoenergetic images (VMI_low) is frequently used to improve visualization of lesions and structures taking up contrast media. This study aimed to evaluate this concept in reverse. Hence to investigate if increased attenuation within the liver allows for improved visualization of little or not-enhancing lesions. METHODS: A 3D-printed phantom mimicking the shape of a human liver exhibiting a lesion in its center was designed and printed. Both, parenchyma- and lesion-mimic were filled with different solutions exhibiting 80/100/120HU and 0/15/40/60HU, respectively. Further, a total of 74 contrast-enhanced studies performed on a spectral detector CT scanner (SDCT) were included in this retrospective study. Patients had MRI or follow-up proven cysts and/or hypodense metastases. VMI of 40-200 keV as well as conventional images (CI) were reconstructed. ROI were placed in lesion and parenchyma(-mimics) on CI and transferred to VMI. Signal- and contrast-to-noise ratio were calculated (S-/CNR). Further, two radiologists independently evaluated image quality. Data was statistically assessed using ANOVA or Wilcoxon-test. RESULTS: In phantoms, S/CNR was significantly higher in VMI_low. The cyst-mimic in highly attenuating parenchyma-mimic on CI yielded a CNR of 6.4 ± 0.8; using VMI_40 keV, mildly hypodense lesion-mimic in poorly attenuating parenchyma-mimic exhibited a similar CNR (5.8 ± 0.9; p ≤ 0.05). The same tendency was observed in patients (cyst in CI/metastasis in VMI_40 keV: 4.4 ± 1.2/3.9 ± 1.8; p ≤ 0.05). Qualitative analysis indicated a benefit of VMI_40 keV (p ≤ 0.05). CONCLUSIONS: VMI_low from SDCT allow for an improved visualization of hypodense focal liver lesions exploiting the concept of contrast blooming in reverse.
Authors: Stefanie Bette; Josua A Decker; Franziska M Braun; Judith Becker; Mark Haerting; Thomas Haeckel; Michael Gebhard; Franka Risch; Piotr Woźnicki; Christian Scheurig-Muenkler; Thomas J Kroencke; Florian Schwarz Journal: Diagnostics (Basel) Date: 2022-05-14
Authors: Hyo-Jin Kang; Jeong Min Lee; Sang Min Lee; Hyun Kyung Yang; Ri Hyeon Kim; Ju Gang Nam; Aruna Karnawat; Joon Koo Han Journal: BMC Med Imaging Date: 2019-08-28 Impact factor: 1.930
Authors: Jasmin A Holz; Hatem Alkadhi; Kai R Laukamp; Simon Lennartz; Carola Heneweer; Michael Püsken; Thorsten Persigehl; David Maintz; Nils Große Hokamp Journal: Sci Rep Date: 2020-12-09 Impact factor: 4.379
Authors: R P Reimer; N Große Hokamp; A Fehrmann Efferoth; A Krauskopf; D Zopfs; J R Kröger; T Persigehl; D Maintz; A C Bunck Journal: Eur Radiol Date: 2020-11-12 Impact factor: 5.315
Authors: Robert Peter Reimer; Nils Große Hokamp; Julius Niehoff; David Zopfs; Simon Lennartz; Mariam Heidar; Roger Wahba; Dirk Stippel; David Maintz; Daniel Pinto Dos Santos; Christian Wybranski Journal: PLoS One Date: 2021-06-15 Impact factor: 3.240