Literature DB >> 30527159

Performing Cardiac Magnetic Resonance Imaging in Patients With Cardiac Implantable Electronic Devices: A Contemporary Review.

Sarah Blissett1, Michael Chetrit2, Bojan Kovacina3, Vartan Mardigyan2, Jonathan Afilalo4.   

Abstract

There are expanding indications for cardiac magnetic resonance imaging (CMR) in patients with cardiac implantable electronic devices (CIEDs). The presence of a CIED had been regarded as a contraindication to CMR due to concerns of arrhythmias, significant changes to lead parameters, and detrimental changes to device programming. The risk of these potential adverse events is theoretically higher in patients undergoing CMR as compared with other anatomic sites. Recent studies have observed low rates of adverse events in patients undergoing CMR (< 1% to 2%), prompting a shift in the recommendations on CMR in patients with CIEDs. The 2017 Heart Rhythm Society Expert Consensus Statement now states that CMR can be performed in patients with both conditional and nonconditional CIEDs at a magnetic strength of 1.5 T, provided there are no fractured, abandoned, or epicardial leads and modifications to MRI parameters are made. The purpose of this review is to (a) outline the potential concerns of performing CMR in patients with CIEDs, (b) define categories of CIEDs as they pertain to MRI safety, (c) summarize the emerging data on adverse events, and (d) provide a practical approach, integrating the key modifications required to perform CMR in patients with CIEDs.
Copyright © 2018 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2018        PMID: 30527159     DOI: 10.1016/j.cjca.2018.09.009

Source DB:  PubMed          Journal:  Can J Cardiol        ISSN: 0828-282X            Impact factor:   5.223


  3 in total

1.  MANAGEMENT OF PATIENTS WITH CARDIAC IMPLANTABLE ELECTRONIC DEVICES UNDERGOING MAGNETIC RESONANCE IMAGING - PROPOSAL FOR UNIFIED HOSPITAL PROTOCOL: CROATIAN WORKING GROUP ON ARRHYTHMIAS AND CARDIAC PACING.

Authors:  Nikola Pavlović; Kristijan Đula; Ivan Kuharić; Sandro Brusich; Vedran Velagić; Zrinka Jurišić; Zoran Bakotić; Ante Anić; Borka Pezo Nikolić; Vjekoslav Radeljić; Zlatko Čubranić; Ivan Zeljković; Dijana Zadravec; Šime Manola
Journal:  Acta Clin Croat       Date:  2020-03       Impact factor: 0.780

2.  Safety and image quality of cardiovascular magnetic resonance imaging in patients with retained epicardial pacing wires after heart transplantation.

Authors:  Constantin Gatterer; Marie-Elisabeth Stelzmüller; Andreas Kammerlander; Andreas Zuckermann; Martin Krššák; Christian Loewe; Dietrich Beitzke
Journal:  J Cardiovasc Magn Reson       Date:  2021-03-15       Impact factor: 5.364

3.  Signal voids of active cardiac implants at 3.0 T CMR.

Authors:  Theresa Reiter; Ingo Weiss; Oliver M Weber; Wolfgang R Bauer
Journal:  Sci Rep       Date:  2022-04-15       Impact factor: 4.996

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.